How to clean the pump.
Generally, the pump does not require disassembly after each brew day, simply recirculating
cleaner and sanitiser through it will break down and dissolve any proteins, minerals or
contaminants present in the pump.
The pump on the Gen 4.0 BrewZilla is easily accessible by simply flipping the brewery over if
you decide you wanted to perform a thorough clean or your pump happens to become
stuck.
If you have a blocked pump you may need to disassemble the pump. To Disassemble the
pump, detach all hosing first and then unscrew the pump from the brewery. Then remove
the screws that hold the pump head on and check the pump head for debris and or solids
that could be stuck in the pump head. Remove the impeller and check if for damage or any
blockage that could be stopping it from spinning. Look in the impeller housing and confirm
no blockages are within this housing.
NOTE: Never direct a garden hose down the pump inlet or recirculation arm as this can
result in the silicone hosing rupturing due to the high pressure of mains water.
Troubleshooting Registration and Telemetry
If you are experiencing issues receiving telemetry or sending a profile to your BrewZilla from
the RAPT portal then you should first check that your BrewZilla controller is connected to
your home Wi-Fi network and that your device is correctly registered. If the device is
connected to your home Wi-Fi network and you are still experiencing issues, then you may
need to re-register your BrewZilla with the RAPT Portal.
How to re-register your BrewZilla Controller
1.
On your BrewZilla controller enter the
Settings Menu
and then navigate to
Clear
Registration
and press
Select
to clear the device registration.
2.
Open the RAPT Portal (app.rapt.io) and click on the edit button of the BrewZilla
controller you wish to re-register.