FIRST USE
Spirit installation manual
page 28
2. Get the main controller in programming mode (to get a long lasting flow of hot water):
Touchpad
:
press and hold upper button on left hand touchpad;
Bastone-autostop
: two-way switch of left
hand group in left position, press and hold program button for 6 seconds
(LED’s will start flashing).
3. Within 4 seconds, activate water dispensing by pressing down and releasing the hot water lever.
Water will start flowing
(LED’s are now lit).
4. Measure the temperature of the outflowing water with a quick-response temperature sensor* and
then de-activate the hot water by pressing down and releasing the lever again. We recommend a
water temperature of around 95 °C.
5. If the temperature is too low: decrease pump pressure of the steam/hot water boiler pump. If the
temperature is too high: increase pump pressure (see Figure 17).
6. After adjusting the pump pressure, make sure that the boiler is at operational temperature and
measure the hot water temperature again.
7. When the required temperature is reached, reset the hot water timer to the desired amount of
water (see section
“set hot water dosage”).
*
If you do not have a quick response temperature sensor, decrease the pump pressure until
boiling water is flowing from the spout (flow will sputter instead of dispensing a calm flow). Then
increase the pump pressure a little until a calm flow is obtained.
Note!
Do not adjust the temperature of the hot water by changing the temperature of the steam/hot
water boiler as this will decrease the temperature stability of the machine.