Small, Medium, Large and XL-Con
After charging
(Indication: Full LED flashing):
The “after charging” phase is the phase where the battery under a
constant voltage is charged to app. 100% of the full capacity. The
voltage is raised 0.4V compared to the Bulk charging phase.
Testing
(Indication: Full LED flashing):
The “testing” phase is the phase where the battery is tested for a
defect battery cell.
Maintenance
(Indication: Full LED constant):
The purpose with “maintenance” phase is to keep the battery
fully charged over a long period of time. The charger is at all time
measuring the voltage and when it goes below 12,8 / 25,6 V it will
start charging the battery.
Boost
(Indication: Discharged LED flashing):
The “Boost” phase is used to kick-start the battery if it has low
power. This “Boost” is made as an intelligent boosting.
This means that the charger is boosting the battery for 1 hour with
maximum current and then the battery is tested to see if it is ready
for normal charging. If the battery is not ready for normal charging,
the charger will boost again. This process is repeated 4 times and
if the battery is not Ok after that the charger will indicate a fault.
Please note that spark protection is not active when in
supply mode.