PRECONDITIONS

BUILDING NOTICE

When you install a stove and erect a chimney, you 

must give building notice to the local Planning and 

Building Committee. Contact the Planning and Build

-

ing Committee in your municipality for up-to-date 

information.

DISTANCE TO FLAMMABLE STRUCTURAL 
UNITS

Before deciding where to place the stove, you must 

localise the beams in the ceiling and the roof in order 

to determine whether it is feasible to install a chimney 

in the desired place.

The K700 must be placed at a distance of 100 mm 

from flammable walls. To maintain the distance of 

100 mm from flammable walls for

 

top connected 

stoves, the chimney flue must be semi insulated. 

(For 

further info, see page 8, point 4.)

The distance from the side of the stove to a per

-

pendicular wall must be at least 350 mm ventilated 

space. (See the illustration below).

For corner placement, the minimum distance to flam

-

mable walls is 100 mm. This is measured at an angle 

of 45 degrees from the rear corners of the stove. 

(See the illustration below).

The stove may be placed closer than the dimensions 

given above, if the wall is not flammable, however, 

not closer than 50 mm.

The distance to flammable walls in front of the stove 

must be at least 1.1 m.

LOAD-BEARING SURFACE

Check that the floor joists have sufficient load-bearing 

capacity. The stove and the chimney can normally be 

placed on an ordinary timber joist floor, if their total 

weight does not exceed 400 kg.

FLOOR PLATE

A floor plate must be set in place to protect the floor 

from flying embers. The floor plate must extend at least 

300 mm in front of the door. The width of the floor plate 

must be at least the width of the hearth plus 100 mm 

on each side. 

The floor plate can consist of natural stone, concrete, 

clinker tiles or 0.7-mm steel plate.

Naturally, you can use Keddy's own floor plate or floor 

glass. These are installed after completing the installa

-

tion of the stove.

OUTDOOR AIR SUPPLY

For the combustion of wood air/supply air is required. 

The K700 can be provided with an external air supply, 

which is recommended for properties with mechanical 

ventilation, see also under the heading "Good to know" 

on page 10.

A sheet metal drum is used for drawing an outdoor air 

duct. The connection diameter of the supply air hose 

to the stove is 100 mm. If the duct is more than 3 m 

long, the diameter of the sheet metal drum must be in

-

creased to 125 mm. The drum can be connected from 

below or from the rear, see the illustration on page 5. 

(A stove's maximum need for combustion air is approx. 

20 m3/h)

Do not take the supply air from crawl spaces. If there is 

a crawl space, the sheet metal drum must be extended 

to a valve in the foundation wall. If the space is heated, 

the supply air channel must be insulated against con

-

densation. 

FLUE

The K700 must be connected to a flue approved for at 

least 350ºC. As the area, length and material of the flue 

are of great importance for the draught formed in the 

flue, it is important the flue is not under-dimensioned.

The minimum recommended chimney length is 3500 

mm, measured from the top of the stove, and the suit

-

able area is 115-175 cm

(approx. 125mm in diameter).

The K700 is also approved for connection to older ma

-

sonry chimneys with enclosing walls that are only half a 

brick thick.

Naturally, the K700 can also be connected to chimneys 

made of prefabricated elements, e.g. the Heda Chim

-

ney.

CHIMNEY CONNECTIONS

The illustration on page 11 shows the distance from the 

rear edge of the stove to the centre of the chimney. If 

you add the distance to the wall, you obtain the position 

of the flue in relation to the wall. There is an illustration 

on page 6 for connection to an existing flue.

Read the chimney's installation instructions before 

starting on the preparations for the chimney and its 

connection.  

- 4 -

Summary of Contents for K700

Page 1: ...K700 Installation Instructions Care and firing instructions...

Page 2: ...plate Outdoor air supply Flue Chimney connections PREPARATIONS 5 7 Flue connections for rear and top installation Floor plate and outdoor air connection Unpacking Dismantling INSTALLATION INSTRUCTION...

Page 3: ...sional perform the installa tion Our dealers can recommend suitable fitters You can find information about our dealers on www keddy se The Clean Air Act 1993 and Smoke Control Areas Under the Clean Ai...

Page 4: ...an use Keddy s own floor plate or floor glass These are installed after completing the installa tion of the stove OUTDOOR AIR SUPPLY For the combustion of wood air supply air is required The K700 can...

Page 5: ...stallation Alternative 2 Top installation Height from the floor to the centre of the flue at the rear 665 mm Height from the floor to the height of the connection top 820 mm Outer diam of the rear top...

Page 6: ...he connecting pipe passes through a flammable wall The flammable wall therefore must be furnished with a shaft with fire retardant lining Masterboard Minerit or equivalent and be insulated with at lea...

Page 7: ...heck horizontally and vertically with the help of a spirit level is on the hearth s sealing plate Tip The stove is vertical and horizontal when the door stays open at an opening an gle greater than 90...

Page 8: ...s leave at least 10 mm of venti lated space between the top of the stove and the chimney s insulation outer steel jacket see illustration The first section of the chimney is normally half insulated ap...

Page 9: ...harmful for both people and the environment BEFORE FIRING WHEN THE STOVE IS NEW During the first week firing can be started carefully Start with one to two fires during the first couple of days A par...

Page 10: ...t that you turn off the ventilation temporarily or open a window until the negative pressure has dissipated If there is insufficient burning material in the firebed to light a new fuel charge excessiv...

Page 11: ...NSIONS AND PERFORMANCE Height 820 mm Width 564 mm Depth 425 mm Weight 170 kg Height centre rear connection 665 mm Height top connection 820 mm Outer dimensions connection sleeve 125 mm Useful efficien...