. 安装主模块

1

) 在

A1、A2、A3、A4

所示的十字光标处用钻头打孔(直径约为

8mm),

并敲入膨胀螺管(共

4

颗)。

【注意】

主模块右边区域为硬盘抽拔区,挂置在距离墙边或其他障碍物≥400mm处。

主模块与扩展坞背面右上角都有拨码开关并贴有调节开关的信息标签,标签信息如下表。确认安装
时,需先按照指示调整拨码开关。例如:主模块安装之前,将

SW1

SW2

的开关均调至

OFF

状态。

SW1

SW2

备注

OFF

OFF

主模块(

A

OFF

ON

扩展坞(

B

ON

OFF

扩展坞(

C

ON

ON

扩展坞(

D

2

. 拨码设置

安装时左边缘
对齐参考线

2

 确定打孔位置

A1

A2

A3

A4

430mm

5

1

0

m

m

3

2

0

m

m

95mm

240mm

3

Summary of Contents for ZCS-KDCA1

Page 1: ...Quick Start Guide Data Docking Station...

Page 2: ...www kedacom com 1...

Page 3: ...2 AC100V 240V 50 60HZ 7 24 250W 10 C 55 C 10 95 RH 4 3 1 1...

Page 4: ...3 1 A1 A2 A3 A4 8mm 4 400mm SW1 SW2 OFF SW1 SW2 OFF OFF A OFF ON B ON OFF C ON ON D 2 2 A1 A2 A3 A4 430mm 510mm 320mm 95mm 240mm 3...

Page 5: ...4 2 A1 A2 A3 A4 5 10mm 3 5 10mm 3 4...

Page 6: ...1 A1 A2 8mm 2 4 A1 A2 510mm 320mm 78mm 95mm 95mm 207mm 5 5...

Page 7: ...6 6 2 A1 A2 5 10mm 3 A1 A2...

Page 8: ...1 2 3 4...

Page 9: ...ality When it is necessary to replace a part please contact your dealer in advance and replace the part with specified model or part with same features We shall not assume any responsibility for probl...

Page 10: ...er Consumption Working Environment Temperature and Humidity Working Temperature Relative Humidity 250W 10 C 55 C 10 95 RH non condensing 1 Install Hard Disk Picture 1 Install hard disks Hard disk hold...

Page 11: ...other obstacles There are dial switches and tags at the top right corner on the back of the main module and the docks The tags are indicated below When installing the device please adjust the dial swi...

Page 12: ...rew bolts external Picture 3 Fix screw bolts Tapping screw bolt 3 Align the left side of the device to the reference lines for installation Place the device downward from the top and lock the hardy ho...

Page 13: ...A1 and A2 and then strike the expansion screw tubes into the holes 2pcs in total 4 Install Docks A1 A2 510mm 320mm 78mm 95mm 95mm 207mm Picture 5 Con rm hole position Alignment reference line at top e...

Page 14: ...ew bolts external 3 Align the top and the left sides of the dock to the reference lines for installation and thus the hardy holes at the back of the device will be able to hang on the tapping screw bo...

Page 15: ...rranty does not apply a to consumable parts such as batteries unless failure has occurred due to a defect in materials or workmanship b to cosmetic damage including but not limited to scratches dents...

Page 16: ...using new or previously used parts that are equivalent to new in performance and reliability or ii exchange the Kedacom Product for a refund of your purchase price A Kedacom replacement part or produ...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...6841 8188 Fax 86 512 68412699 Suzhou Keda Technology Co Ltd Singapore 627A Aljunied Road 09 07 BizTech Centre Singapore 389842 Tel 65 6842 5700 Fax 65 6842 5900 05 03 800475 V1 20170120 Overseas Hotl...

Reviews: