ELECTRIC BICYCLE METER KT—LCD3 Product User Manual
- 26 -
C4 value
Handlebar startup mode P4=0
Handlebar startup mode P4=1
0
zero startup handlebar
Non-zero startup handlebar
1
Zero startup, handlebar speed limit is
6Km/h
Before power assist, the handlebar speed limit is
6Km/h, after power assist, handlebar is full speed.
2
Zero startup, handlebar speed limit is
specified
Non-zero startup, handlebar is specified speed
limit.
3
Zero startup, Zero gear effectively
Retain
4
Handlebar gears is distinguished
according to the display meter.
Handlebar gears is distinguished according to the
display meter.
5
Retain
Retain
After finishing C4 parameter setting, hold
button (SW) shortly to save the
current set values and enter C5 parameter setting interface.
○
C5
Controller Maximum Current Adjustment Mode
Enter C5 parameter setting interface after C4 parameter setting is finished, C5
parameter column flashes.
C5 parameter setting interface
C5 is controller maximum operating current adjustment mode (tiny-adjustment of
limit current value). The default value is 10, setting range is 0-10, hold
button (
UP
)
or
button
(DOWN)
shortly for selection.
C5 parameter definition table
:
C5 value
Maximum current value(A)
00
Undefined