![Keba ServoOne CM Series Operation Manual Download Page 26](http://html.mh-extra.com/html/keba/servoone-cm-series/servoone-cm-series_operation-manual_660467026.webp)
26
Electrical installation
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
Electrical installation
Abbreviation
Designation
Details
24 V DC/GND
24 V control supply output via busbars
DC Link +/-
DC link supply output via busbars
X11
Connection for braking resistor
X2
24 V control supply input via terminals
X3
Cross-communication output (XC OUT)
(X3)"
X5
Relay contact (RO02), programmable
X6
Relay contact (RO01)
Digital outputs (TPO0, TP01)
Quick shutdown EXP-/EXP+
Power failure PF
LINE IN
DC link pre-charging mains input
(L1, L2, L3/3 x 230/400/480 V AC)
X1/
ϑ
BR
Connection for temperature monitoring braking resistor
(Klixon)
X1/
ϑ
1
Connection for mains filter temperature monitoring
(Klixon)
X1/
ϑ
2
Connection for mains choke temperature monitoring
(Klixon)
PE
Protective earth conductor connection
Shield connection, control cable
PE connection
Table 4.1
Key to the layout, ServoOne CM-L charging module
4.3.2
Connections, ServoOne CM-A active supply unit
SO CM-A.00L2
X3 XC IN
X4 XC OUT
X5.1 EtherCAT® IN
X5.2 EtherCAT® OUT
X6/DI
DC-Link +
DC-Link -
+ 24 V DC
GND
X11 Safe-DI
LINE FILTER
SYNC
LC (T
emp)
+ ZK -
LC (Temp)
PE connection
Figure 4.3
Layout, ServoOne CM-A active supply unit SO CM-A.00L2