![Keba ServoOne CM Series Operation Manual Download Page 8](http://html.mh-extra.com/html/keba/servoone-cm-series/servoone-cm-series_operation-manual_660467008.webp)
8
General
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
General
Mac Adr.:
SW:
FS SW1:
SN:
SN:
FS SW2:
Industrial Automation
Germany GmbH
35633 Lahnau
Gewerbestraße 5-9
Multiple rated equipment. See instruction manual
In:
Out:
Year:
T1
T
SO CM-A.00L4.0000.0
JJWWSXXXX
400 V - 480 V 3ph
2019
50/60 Hz, 79 A-67 A
600 V - 750 V DC
91 A - 73 A DC
JJWWSXXXX
MACADR
V 0.1
SO CM-A.00L4.0000.0
A
Serial no. key:
- JJ (YY) = Prod. year
- WW = Calendar week (CW)
- S = Production site
- XXXX = Sequential no. per CW
A: Revision state e.g. F
Figure 1.3 Hardware rating plate, ServoOne CM-A SO CM-A.00L4.0000.0 (example)
T
T1
Figure 1.4 Position of rating plate (T)
Figure 1.5 Position of second rating plate (T1)
A second rating plate (T1) with only the most important information is on the top of
the busbar cover. In this way the rating plate data can also be seen if the devices are
installed in a row.
1.8 Brief description
NOTE
Only the ServoOne CM-L charging module and the
ServoOne CM-A active supply unit are described in this operation manual.
You will find information on other components in the related operation
manuals.
The ServoOne CM-L charging module (SO CM-L) and the
ServoOne CM-A active supply unit (SO CM-A) with energy recovery are components of
the multiple axis automation system SystemOne CM and are always used together.
ServoOne CM-L charging module
The ServoOne CM-L charging module (BG1) is used for pre-charging the DC link, for
the connection of the braking resistor and for the supply of the 24 V control voltage. The
maximum braking power is 115 kW. The maximum capacitance of the DC link that can
be pre-charged is 40000 µF.
ServoOne CM-L charging module for pre-charging
Unit
SO-CM-L.0000
Maximum braking power
kW
115
Continuous braking power
kW
6
Mains voltage
V AC
3 x 230 – 480
Tolerance on the supply voltage
± 10 %
Control voltage 24 V
With external switched-mode power supply via busbars
or connection to separate connectors.
For further technical data, see “A.1 Technical data,”.