14
Mechanical installation
Operation Manual Supply Unit SO CM-P BG1+2
ID no.: 1400.201B.5-00 Date: 02/2020
Mechanical installation
3.2 Mounting clearances
CAUTION!
Damage to the device due to incorrect installation conditions!
The device may suffer irreparable damage if the conditions are not met.
x
The minimum clearances stated in the figure below apply to all devices (MotionOne CM,
ServoOne CM-P and ServoOne CM).
x
The clearance above the devices is important to prevent the build-up of heat. The clearance
underneath and at the front is necessary to permit correct cable laying.
≥
130
≥
150
*)
≥
300
SOCMP-BG1
Figure 3.2
Mounting clearances, SystemOne CM-P supply unit
≥
130
≥
200
*)
≥
300
SOCMP-BG2
*) The bending radius of the connection cables must be taken into account:
The mains connection cable for the supply unit is definitive for the clearance underneath.
Bending radius mains cable up to 3 x 10 mm
2
(for SOCM-P-BG1)
Bending radius mains cable up to 3 x 16 mm
2
(for SOCM-P-BG2)
Approx. 48 to 98 mm (depending on cable type)
Approx. 150 to 200 mm (depending on cable type)
Figure 3.2
Mounting clearances, SystemOne CM-P supply unit