Safety notes for personal safety

WARNING!

Health hazard for persons with pacemakers, metallic implants and hearing
aids!

The device is equipped with magnets. Magnets can affect the function of pacemak-
ers and implanted defibrillators. A pacemaker can be switched into test mode and
cause discomfort. A defibrillator may stop working in some cases.

WARNING!

Danger due to lithium polymer batteries

This device contains rechargeable lithium polymer batteries

In the event that these instructions are not observed, the device can explode, fire
may ignite and a formation of smoke may develop. Furthermore, impaired function
may result and safe operation cannot be ensured.

The device must never:

be disassembled or modified in any form

be exposed to heat or burned

be used when it is damaged

be operated with a power supply unit other than that specified

be pierced through with foreign objects (for example, nails), impacted or kicked

be subjected to an impact load or sliding movement

be placed in a microwave device or a high-pressure vessel

be operated in an improper state (for example, with batteries that are becoming
drained or in the event of a deformed enclosure).

CAUTION!

LASER RADIATION 
DO NOT LOOK INTO THE BEAM
LASER CLASS 2

IEC 60825-1:2014 
660 nm; 7 mW; pulsed

The laser beam must not be pointed at persons or animals. Avoid looking into the
direct or reflected laser beam.

The device must be switched off again after use. Ensure that it is not used by un-
qualified personnel at any time.

Summary of Contents for KeMes A1 Series

Page 1: ...ety of the product Information The current operating instructions are available in German English Spanish Ital ian and French and can be downloaded directly from the KEBA website http www keba com kem...

Page 2: ...n cannot be ensured The device must never be disassembled or modified in any form be exposed to heat or burned be used when it is damaged be operated with a power supply unit other than that specified...

Page 3: ...off the device from the main menu Press and hold Navigate forward within the menu level Increase set value Switch from individual measurement to continuous measure ment Execute selected action Press 1...

Page 4: ...limited accuracy Surface Easy to measure Not measurable hard to measure2 Smooth surface x Sheets with protective foil x Clean surface x Heavily scaled sheets x Electrolytically galvanized sheets for...

Page 5: ...pressing the operating button 3 Navigate to the Manual menu item by pressing and holding the operating button 4 Place the device close to the workpiece so that the measuring aid touches the bending e...

Page 6: ...on vertical surfaces Measurement at the press brake machine mode 1 Attach the device to the upper tool 2 Switch the device on by pressing the operating button 3 Navigate to the Machine menu item by pr...

Page 7: ...ction is set up and how the device is coupled to the receiver depend on the version and are described in the operating instructions Sending measured values after a manual measurement valid for A2xx If...

Page 8: ...bient conditions Operating temperature 5 C to 40 C Charging temperature 5 C to 40 C Storage temperature 20 C to 45 C Relative air humidity 5 to 95 non condensing Laser Laser class 2 in accordance with...

Page 9: ...EU Declaration of Conformity...

Page 10: ......

Page 11: ...FCC Supplier s Declaration of Conformity...

Page 12: ...FCC Supplier s Declaration of Conformity...

Reviews: