KC-P30 x-series
Functions
Configuration manual V4.09
33
© KEBA
Entry
Description
Master RFID Card
Set the RFID card as master RFID card. Only one card can be
defined as master RFID card.
Status
Authorization of the RFID card. Here it is also possible to block
an RFID card and thus prevent charging with the relevant RFID
card.
Charging Station –
Serial No.
Serial number of the charging station where the RFID card may
be authorized. All or only certain charging stations in the charg-
ing network can be enabled for the RFID card.
5.2.4
RFID authorization with OCPP backend connection
If the charging station or a charging network is controlled by an OCPP back-
end, please note the following:
●
Teach in RFID cards:
All RFID cards must be "centrally taught in" at the OCPP backend.
●
"Authorization" in the web interface to "ON":
Each authorization request is relayed to the OCPP backend.
●
"Authorization" in the web interface to "OFF":
A charging process can only be started without holding up an RFID card
if the predefined token set in the configuration is recognized and ac-
cepted by the OCPP backend.
Information
For information on the functionality and the required settings of the OCPP
backend, refer to the specific manual of the system used.
5.2.5
Start charging process with RFID authorization
To start a charging process with RFID authorization, proceed as follows:
1) Plug the vehicle into the charging station.
2) Hold the RFID card, which was previously taught in, in front of the RFID
reader.
3) The rising tone sequence and the green flashing LED bar indicate that
the RFID card has been accepted.
The charging process can now be started by the vehicle.
4) If necessary, the charging process can be stopped prematurely by hold-