![background image](http://html2.mh-extra.com/html/keba/kecontact-p30/kecontact-p30_udp-programmers-manual_3824963032.webp)
P30
UDP commands
UDP Programmers Guide V2.01
32
© KEBA
3.3.2
UDP command: curr
The command
curr
can be used to control the target charging current at any
time. This command directly changes the value in the "Curr user" field in
re-
port 2
. All changes made by
curr
are permanent until the device is re-