KC-S10
Mounting and installation instructions
V
14
© KEBA 2022
6
Mounting and installation instructions
The device must be installed on a wall in the vertical position.
Fastening materials (anchors, screws, etc.) are not included in the scope of
delivery. Proper installation is absolutely necessary and lies outside of the
scope of responsibility of the manufacturer.
WARNING!
Risk of electric shock and fire hazard!
For installation on hollow walls, at least two mounting screws must be se-
cured to a support element of the wall. Special hollow-wall anchors must be
used for the other mounting screws. It is particularly important to make sure
the substructure has sufficient load-bearing capacity.
Caution
Property damage due to dampness and moisture!
●
Installation and commissioning must be done in a suitable environment.
The device must be protected against rain, snow and dirt. If installed out-
doors, the connection panel cover is not permitted to be opened in case
of rain, wind or snow.
●
Only vertical installation on a wall is permitted.
●
Do not subject the device to high humidity for a longer period of time.
●
If a cold device is brought into a significantly warmer environment (e.g.
after extended transport in a cold environment), condensation moisture
may form in the device.
Before connecting to the power supply, you must wait until the tempera-
ture of the device is the same as the room temperature and the moisture
has evaporated again.
Caution
Risk of breaking the plastic housing!
●
Do not tighten the mounting screws with force (max. 1.2 Nm).
●
The mounting surface must be completely flat. Warpage of the housing
must be prevented.
●
If adjustment is necessary, washers must be used.
6.1
General criteria for the site selection
The device was designed for indoor and outdoor use. Accordingly, it is nec-
essary to ensure the correct set-up requirements and the protection of the
device at the installation site.
The following criteria must be taken into account when selecting a location: