3.1.2 Mechanical ambient conditions
Storage
Standard
Class
Notes
Vibration limits
EN 60721-3-1
1M1
Vibration amplitude 0.3 mm (2…9 Hz)
Acceleration amplitude 1 m/s² (9…200 Hz)
Shock limit values
EN 60721-3-1
1M1
40 m/s²; 22 ms
Transport
Standard
Class
Notes
Vibration limits
EN 60721-3-3
2M1
Vibration amplitude 3.5 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
Acceleration amplitude 15 m/s² (200…500 Hz)
Shock limit values
EN 60721-3-2
2M1
100 m/s²; 11 ms
Operation
Standard
Class
Notes
Vibration limits
EN 60721-3-3
3M4
Vibration amplitude 3.5 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
ISO 4762
1 A
Railway applications
Attached to the vehicle body.
Shock limit values
EN 60721-3-3
3M4
100 m/s²; 11 ms
Pressure in the water cooler
–
–
Max. operating pressure: 10 bar
Table 3:
Mechanical ambient conditions
3.1.3 Chemical / mechanical active substances
Storage
Standard
Class
Notes
Contamination
Gases
EN 60721-3-1
1C2
–
Solids
1S2
–
Transport
Standard
Class
Notes
Contamination
Gases
EN 60721-3-2
2C2
–
Solids
2S2
–
Operation
Standard
Class
Notes
Contamination
Gases
EN 60721-3-3
3C2
–
Solids
3S2
–
Table 4:
Chemical / mechanical active substances
26
OPERATING CONDITIONS
All manuals and user guides at all-guides.com