background image

GB - 6

Preface

Tests can only be done within the application by the machine manufacturer. They must be 

repeated, even if only parts of hardware, software or the unit adjustment are modified. 

Unauthorised opening and tampering may lead to bodily injury and property damage and 

may entail the loss of warranty rights. Original spare parts and authorized accessories by the 

manufacturer serve as security. The use of other parts excludes liability for the consequences 

arising out of.

The suspension of liability is especially valid also for operation interruption loss, loss of profit, 

data loss or other damages. This is also valid, if we referred first to the possibility of such 

damages.
If single regulations should be or become void, invalid or impracticable, the effectivity of all 

other regulations or agreements is not affected.

1.4 Copyright

The customer may use the instruction manual as well as further documents or parts from it for 

internal purposes. Copyrights are with KEB and remain valid in its entirety. All rights reserved.
KEB

®

, COMBIVERT

®

, COMBICONTROL

®

 and COMBIVIS

®

 are registered trademarks of Karl 

E. Brinkmann GmbH.
Other wordmarks or/and logos are trademarks (™) or registered trademarks (®) of their re-

spective owners and are listed in the footnote on the first occurrence.

When creating our documents we pay attention with the utmost care to the rights of third par-

ties. Should we have not marked a trademark or breach a copyright, please inform us in order 

to have the possibility of remedy.

1.5 

Specified application

The COMBIVERT G6 serves exclusively for the control and regulation of three-phase motors. 

The operation of other electric consumers is prohibited and can lead to the destruction of the 

unit. Frequency inverters are components which are intended for the installation in electric 

systems or machines.
The used semiconductors and components of KEB are developed and dimensioned for the 

use in industrial products. If the KEB COMBIVERT F5 is used in machines, which work under 

exceptional conditions or if essential functions, life-supporting measures or an extraordinary 

safety step must be fulfilled, the necessary reliability and security must be ensured by the ma

-

chine builder. The operation of our products outside the indicated limit values of the technical 

data leads to the loss of any liability claims.

1.6 

Product description

The product family COMBIVERT G6 has been developed for the universal use at open-loop 

three-phase drives. The COMBIVERT G6 can be operated open-loop or encoderless speed 

or torque-controlled. The units are equipped with an integrated EMC filter.

Summary of Contents for COMBIVERT G6

Page 1: ...C O M B I V E R T GB Installation Manual IO link Control Circuit Original manual Mat No Rev 00G6NES E001 1A...

Page 2: ......

Page 3: ...gnment of the interface X4A 11 2 1 4 2 Connection of the RS232 interface 11 2 1 4 3 Connection of the RS485 interface 12 2 1 4 4 Wiring RS485 full duplex 12 2 1 4 5 Wiring RS485 half duplex 13 2 1 5 C...

Page 4: ...GB 4 Table of Contents...

Page 5: ...ing or operation of the unit Aide Tip 1 2 Safety instructions Observe safety and operating instruc tions Precondition for all further steps is the knowledge and ob servance of the safety and operating...

Page 6: ...ir re spective owners and are listed in the footnote on the first occurrence When creating our documents we pay attention with the utmost care to the rights of third par ties Should we have not marked...

Page 7: ...display not valid for customer special version 0 Open loop without keyboard display A like 0 on ASCL hardware 1 Open loop with keyboard display B like 1 on ASCL hardware 2 SCL without keyboard display...

Page 8: ...th f 0Hz 3 internal filter with braking transistor without safety function STO D like 3 with STO L like D with f 0Hz Control type C Analog digital standard GB CAN 1 E IO Link 2 F EtherCAT 3 G PROFINET...

Page 9: ...to EN61800 5 1 base TN C S mains LED for inverter state optional with safety function STO separate manual optional f 0Hz functionality separate manual 2 1 Overview No Name Description 5 4 3 1 2 X2B X...

Page 10: ...ction AWG Metal sleeve length Stripping length Cross section AWG Stripping length 0 2 0 75mm2 24 19 6mm 8 mm 0 2 1 5 mm2 24 16 10mm Connecting wires rigidy and flexible 2 1 3 Assembly of the wires Req...

Page 11: ...an be done via the KEB homepage Interface Standard Connecting cable RS485 TIA EIA 485 and ISO 8482 RS232 ANSI TIA EIA 232 0058025 001D RS232 USB 0058060 0020 2 1 4 1 Assignment of the interface X4A 5...

Page 12: ...ir of wires of the communication bus if available the internal shielding must be laid at the transmitter to ground Lay earth cable between the bus nodes A biasing can be used if there are still interf...

Page 13: ...functional earth is connected correctly potential differences be tween the bus nodes can occur at long lines which disturb the communica tion To avoid the interface from destruction by high circulati...

Page 14: ...ing length Cross section AWG Stripping length 0 50mm2 21 10mm 12mm 0 14 1 5 mm2 25 16 10mm 0 75mm2 19 12mm 14mm Connecting wires rigidy and flexible 1 00mm2 18 12mm 15mm Press pusher by hand Insert co...

Page 15: ...EC61131 2 type 1 0 3 5VDC 1 15 30VDC Scan time 2ms 6 ST 1 Control release 7 R Direction of rotation re verse 8 F Direction of rotation for ward 9 I2 Digital input 2 10 I1 Digital input 1 11 I4 Digital...

Page 16: ...at 1A 30VDC Ohmic load 26 R1 C Relay 1 Switching contact 27 R2 B Relay 2 NC contact 28 R1 B Relay 1 NC contact 29 R2 A Relay 2 NO contact 30 R1A Relay 1 NO contact 31 R3 C 2 Relay 3 switching contact...

Page 17: ...value 3 I2 9 Fixed frequen cy 2 Fixed value 2 I3 12 External error input E EF I4 11 Activates the DC braking 2 1 5 4 Connection of the digital outputs Examples for the connection of the digital output...

Page 18: ...he controls The internal resistance is reduced to 30k Input Factory setting of the setpoint inputs Name PIN AN1 17 18 analog setpoint setting 0 10Vdc AN2 19 20 2 1 5 6 Connection of the analog outputs...

Page 19: ...nection of the relay outputs 262830 252729 R2 R1 Specification U max 30Vdc I 0 01 1A Ohmic load Output Factory setting of the relay outputs Name PIN open loop operation closed loop operation R1 26 28...

Page 20: ...d from parameter CP48 see below CP48 Software version Co domain Setting Description 0 0 0 0 F F F F Display of the software version The first two digits display the major and minor version number e g...

Page 21: ...GB 21 Notes...

Page 22: ...GB 22 Notes...

Page 23: ...GB 23 Notes...

Page 24: ...fr mail info keb fr KEB UK Ltd Morris Close Park Farm Industrial Estate GB Wellingborough NN8 6 XF fon 44 1933 402220 fax 44 1933 400724 net www keb uk co uk mail info keb uk co uk KEB Italia S r l V...

Reviews: