36
DSP402-Parameter
Name:
DSP402_Controlword
Index:
6040h
Subindex:
0
Meaning:
Control word with coding according to
[4]
. The parameter is bit-coded.
Data length:
2 byte
Coding:
Bit-coded according to
[4]
. The following table only lists the bits that are realised in this soft-
ware. Note that some bits are different assigned by the settings of the DSP402-mode (see table
below):
Modes of
operation
b7
b6
b5
b4
b3
b2
b1
b0
Fault
Reset
Mode-dependent
Enable
Operation
Quick
Stop
Ennable
Voltage
Switch
ON
255
„“
Res.
Res.
Res.
„“
„“
„“
„“
2
„“
RFG
Use Ref
RFG
Unlock
RFG
Enable
„“
„“
„“
„“
Default value:
PDO-mapping:
receive PDO
transmit PDO
YES
YES
Note:
This parameter is internally mapped to parameter
Sy.50
.
Name:
DSP402_Statusword
Index:
6041h
Subindex:
0
Meaning:
Status word with coding according to
[4]
. The parameter is bit-coded.
Data length:
2 byte
Coding:
Mode b15... b14 b13
b12
b11
b10
b9
b8... b7
Mode-dependent Int. Limit
Active
Target
Reached
Remote
255
Res.
Res.
„“
„“
„“
„“
2
Res.
Res.
„“
„“
„“
„“
b6
b5
b4
b3
b2
b1
B0
Switch ON
Disabl.
Quick Stop Volt. Enabl. Fault Operation
Enabl.
Switched ON Ready To
Switch ON
„“
„“
„“
„“
„“
„“
„“
„“
„“
„“
„“
„“
„“
„“
Default value:
PDO-mapping:
receive PDO
Transmit PDO
NO
YES
Note:
This parameter is internally mapped to parameter
Sy.51
.
Summary of Contents for COMBIVERT F5
Page 2: ...2...