22
Operator parameters
Name:
Manufacturer Status Register
Index:
1002h
Meaning:
Returns the value of parameter RU.00 as 4 byte value.
Subindex:
0
Data length:
4 byte
Coding:
[3]
Note:
This parameter can be read only.
Name:
Pre-defined error field
Index:
1003h
Meaning:
This parameter contains a field of maximum 6 entries where the error-
history can be read out. Subindex = 0 contains the number of errors that
have been saved whereby the entries with subindex = 1-5 contain the
real error entries
Subindex:
0: number of errors
Data length:
4 byte
Coding:
1
Note:
Writing on subindex = 0 deletes the error-history completely.
Subindex:
1-5: standard error field
Data length:
4 byte
Coding:
according to
[2]
, as follows:
Byte4
Byte5
Byte6
Byte7
ErrorCode
inverter state (ru.00)
LB
HB
LB
HB
Note:
The entries are read-only.
Name:
Manufacturer Device Name
Index:
1008h
Meaning:
Displays the value of parameter inverter identification SY.02 as 4-charac
-
ter hexadecimal coded string.
Subindex:
0
Data length:
4 byte
Coding:
Value 0864Ah/2148 would appear in the CAN telegram as follows:
Byte4
Byte5
Byte6
Byte7
30h:‘0‘
38h:‘8‘
36h:‘6‘
34h:‘4‘
Note:
This parameter can be read only.