31
ANTRIEBSTECHNIK
GB
START
STOP
FUNC.
SPEED
ENTER
F/R
1
2
3
9 10
+
PE
Analog output:
0...10VDC / max. 5mA
at Ri 56 k
Ω
const.
0...1mADC at
Ri
≤
5 k
Ω
const.
3.2.3 Outputs
Installation and Connection
As an accessory to the local operation an operator is necessary. To
prevent malfunctions, the inverter must be brought into
nOP
status
before connecting/disconnecting the operator (open control release
terminal X1.14). When starting the inverter without an operator, it is
started with the last stored values or factory setting. The operator is
obtainable in different versions:
4.
Operation of the
unit
Interface control
Transmit "LED flickers"
Double function keyboard
Operating-/Error display
Normal "LED on"
Error "LED blinks"
5-digit LED Display
4.1
Digital operator
Part-No. 00.F4.010-2009
RS232/RS485
PIN
RS485
Signal
Meaning
1
–
–
reserved
2
–
TxD
Transmitter signal/RS232
3
–
RxD
Receiver signal/RS232
4
A'
RxD-A
Receiver signal A/RS485
5
B'
RxD-B
Receiver signal B/RS485
6
–
VP
Voltage supply-Plus +5V (I
max
= 10 mA))
7
C/C'
DGND
Data reference potential
8
A
TxD-A
Transmitter signal A/RS485
9
B
TxD-B
Transmitter signal B/RS485
PE-Connection
4.1.1 Interface operator
Part-No. 00.F4.010-1009
In the Interface operator there is an additional isolated RS232/RS485-
Interface integrated.
Informations about other versions of operators contact KEB!
Relay output:
30V DC / 1A
1
2
3
4
5
6
7
8
9