6 fieldbus Watchdog
The fieldbus watchdog is a function in the VARAN control board. It is used to trigger an
error or warning in the inverter, if certain events are not cyclically repeated within a cer-
tain time. The activation of the watchdog is set by the control card parameters fb04 and
fb05. The monitoring time and the at exceeding of the monitoring time executed function
is set by parameter in the inverter (pn05, pn06).
Id-Text
Name
Parameter index
fb04
bus watchdog activation
0x2184
Meaning
Allows a delayed activation of the fieldbus watchdog after
switching on the device.
Type
Variable
Data length
8 bit
Access
read / write
Coding
0...65535
Value range
0:
off (fieldbus watchdog inactive)
1:
Activation after the first asynchronous communica
-
tion
16:
Activation after the first received process output
data via isochronous communication
Standard value: 0
Note
Possible settings are OR connected.
Id-Text
Name
Parameter index
fb05
bus watchdog lock
0x2185
Meaning
Determines on which incidents the fieldbus watchdog gets
reseted.
Type
Variable
Data length
8 bit
Access
read / write
Coding
0...65535
Value range
0:
off (no reset)
2:
When receiving an asynchronous communica-
tion request, the watchdog gets reseted.
128:
When receiving of process output data via
isochronous communication the watchdog gets
reseted.
Standard value: 0
Note
Possible settings are OR connected.