View upper side of the device
X2B
X4B
X4C
X4A
X2D
X2C
X2A
X2A
Digital inputs and outputs
Dig. input 4 16 15
0V
Dig. input 3 14 13
0V
Dig. input 2 12 11
0V
Dig. input 1
10
9
0V
Dig. output 4
8
7
0V
Dig. output 3 6
5
0V
Dig. output 2 4
3
0V
Dig. output 1 2
1
0V
X2C
Error chain 2
1 Charging status of the DC link
and error output of the axis
modules
X2D
Error chain 2
1
X4A
reserved 1
6 reserved
TxD (RS232) 2
7 DGND (reference potential)
RxD (RS232) 3
8 TxD-A (RS485)
RxD-A (RS485)
4
9
TxD-B (RS485)
RxD-B (RS485)
5
X4C
EtherCAT out
LED
1
TX+
Speed
2
TX-
3
RX+
4
–
X4B
EtherCAT in
5
–
6
RX-
Link / Activity
7
–
LED
8
–
X2B
Safety module (type 0 „default“ is displayed here)
4 Brake
- no function -
3
0V
Reference potential
2 24V
Output DC 24 V / 100 mA
1 ST
Control release
Figure 15: View upper side of the device
47
INSTALLATION AND CONNECTION
Summary of Contents for COMBIVERT 14H6 Series
Page 2: ......