KEB COMBILINE Service Manual Download Page 4

Service Manual for Medium Frequency Sine-wave Filters

GB-4

Danger by 

high voltage

KEB electronics components contain dangerous voltages which 

can cause death or serious injury. In operation, drive converters, 

depending on their degree of protection, may have live, uninsulated, 

and possibly also moving and hot surfaces.

In case of inadmissible removal of the required covers, of improper 

use,  wrong  installation  or  maloperation,  there  is  the  danger  of 

serious personal injury and damage to property.

      

2. 

Service notes

2.1 

General

The present service manual describes necessary steps at maintenance and repair of medi-

um frequency sine-wave filters. 

The following checks must be done. 

Capacity test of the capacitors

Insulation test of the choke

2.2 

Required tool

Torque spanner with diverse uses

Capacity measuring device

High voltage tester

Additional equipment for the change of the capacitors

Knife

Hot-air fan

Heat-shrinkable tube

2.3 

Life expectancy - exchange of the capacitors

The maximum life expectancy of the capacitors amounts to100,000 operating hours. After 

that the capacitors must be exchanged.

This  information  can  deviate  downwards  dependent  on  the  respective  operating  mode.  

Whether an exchange is necessary results by the following measurement.

2.4 

Checking of the sine-wave filter

2.4.1 

Preparations

switch system de-energized

secure against restart

• await five minutes for discharge of the capacitors
• clean sine-wave filter from dust and other contaminations