KEB COMBICOM Installation Manual Download Page 8

GB -8

Software

3.1 

Manual Driver Installation

1.

The *.inf-file must be assigned once to the system on the PC.

The installation must be made separately for each USB port.

2. The assistent for new hardware opens automatically, if the converter is connected to 

a not yet configured for USB serial converter. 

3.

The USB-inf-file is located in a „USB driver package“. The „USB driver package“ can 

be downloaded under www.keb.de -> Download -> Search for: „USB driver pack

-

age“. Extract the “USB driver package” files after the download.

4.

Set the path in which the "kebcdc.inf" and kebcdc.cat files are found.

5. Finish the installation.

Computers with Windows 7 do not ask for a driver because a ST Electronic driver 

is automatically installed by the system. The function is given, but is recognized 

as USB converter, not as KEB unit.If required it can be replaced manually.

With the KEB-USB converter the parameter files can not be read-out with COM

-

BIVIS 5 from the F5 when connected via HSP5.

3.2 

Use among Combivis 5.6

When using the USB serial converter KEB under COMBIVIS 5.6 some things to consider:

The communication settings are run in serial protocol DIN 66019, even if the converter is con

-

nected to an interface of a HSP5 COMBIVERT F5 or COMBIVERT B6. The protocol HSP5 is 

always converted to DIN 66019.

The RTS delay must be set between 3000ms and 5000ms. By the delay transmission of the 

data is somewhat slowed, whereby the converter has sufficient time to process the data.

Summary of Contents for COMBICOM

Page 1: ...C O M B I C O M GB Installation Manual USB Serial Converter Translation of Original Manual Document Part Version Date 20094859 GBR 00 1014...

Page 2: ......

Page 3: ...1 3 Qualification 5 1 4 Order data 5 1 5 Product description 5 2 Hardware 6 2 1 Description of USB serial converter 6 2 2 Technical data 6 3 Software 7 3 1 Manual Driver Installation 8 3 2 Use among C...

Page 4: ...ves the right to change specifications without prior notice or to instruct third persons The information contained in the technical documentation as well as any user specific advice in spoken and writ...

Page 5: ...EN 60204 as well as those who note the valid local regulations Danger by high voltage KEB electronics components contain dangerous voltages which can cause death or serious injury In operation drive...

Page 6: ...vel USB socket type B Figure 1 USB serial converter 2 2 Technical data General Dimension HxBxL 20 mm x 35 mm x 88 mm Weight 30 g Ambient conditions during operation 10 45 C Ambient conditions at stora...

Page 7: ...al converter The following KEB services are supported see protocol description HSP5 0 Read write the parameter value extended set addressing 1 Read write the parameter value default set addressing 18...

Page 8: ...ws 7 do not ask for a driver because a ST Electronic driver is automatically installed by the system The function is given but is recognized as USB converter not as KEB unit If required it can be repl...

Page 9: ...ly see chapter Manual Driver Installation Excep tion The driver has already been installed automatically by COMBIVIS 6 The COM port used by the USB converter must be entered Located at Windows Control...