KEB COMBICOM Installation Manual Download Page 7

GB -7

Software

3. 

Software

The serial side supports:

• DIN66019 (RS 232)
• HSP5 (TTL level )

The type of interface is automatically detected. 

If the DIN66019 protocol is used on the serial side, the "DIN66019 protocol USB" is only 

physically converted to "DIN66019 protocol RS232" in the USB serial converter and the log 

data remains unchanged. 

If the HSP5 protocol is used on the serial side, the "DIN66019 protocol USB" is converted to 

"HSP5 protocol TTL level" in the USB serial converter. 

The following KEB services are supported (see protocol description HSP5): 

0

Read / write the parameter value (extended set-addressing) 

1

Read / write the parameter value (default set-addressing)

18

Read process data telegram type 3 (Timestamp, 2x32, 2x16 Bit)

No automatic baud rate search is supported. The baud rate is adjusted via the used program 

e. g. The baud rate can be adjusted in the range of 2400 Baud…115.2 kBaud. 

The default value of 38.4 HSP5 kBaud should not be changed. 

At DIN66019 on F5 the value of 9.6 kBaud should be used.

The baud rate of the connected unit (see unit parameter) and the driver setting for 

the used COM port must be adjusted equal.

Summary of Contents for COMBICOM

Page 1: ...C O M B I C O M GB Installation Manual USB Serial Converter Translation of Original Manual Document Part Version Date 20094859 GBR 00 1014...

Page 2: ......

Page 3: ...1 3 Qualification 5 1 4 Order data 5 1 5 Product description 5 2 Hardware 6 2 1 Description of USB serial converter 6 2 2 Technical data 6 3 Software 7 3 1 Manual Driver Installation 8 3 2 Use among C...

Page 4: ...ves the right to change specifications without prior notice or to instruct third persons The information contained in the technical documentation as well as any user specific advice in spoken and writ...

Page 5: ...EN 60204 as well as those who note the valid local regulations Danger by high voltage KEB electronics components contain dangerous voltages which can cause death or serious injury In operation drive...

Page 6: ...vel USB socket type B Figure 1 USB serial converter 2 2 Technical data General Dimension HxBxL 20 mm x 35 mm x 88 mm Weight 30 g Ambient conditions during operation 10 45 C Ambient conditions at stora...

Page 7: ...al converter The following KEB services are supported see protocol description HSP5 0 Read write the parameter value extended set addressing 1 Read write the parameter value default set addressing 18...

Page 8: ...ws 7 do not ask for a driver because a ST Electronic driver is automatically installed by the system The function is given but is recognized as USB converter not as KEB unit If required it can be repl...

Page 9: ...ly see chapter Manual Driver Installation Excep tion The driver has already been installed automatically by COMBIVIS 6 The COM port used by the USB converter must be entered Located at Windows Control...

Page 10: ...GB 10 Notes...

Page 11: ...GB 11 Notes...

Page 12: ...fr KEB UK Ltd Morris Close Park Farm Industrial Estate GB Wellingborough NN8 6 XF fon 44 1933 402220 fax 44 1933 400724 net www keb uk co uk mail info keb uk co uk KEB Italia S r l Via Newton 2 I 200...

Reviews: