background image

4

 Preface

Laws and guidelines

KEB Automation KG confirms with the CE mark and the EC declaration of conformity, 

that our device complies with the essential safety requirements.
The CE mark is located on the name plate. The EC declaration of conformity can be 

downloaded on demand via our website. Further information is provided in chapter 

"Certification".

Warranty

The warranty on design, material or workmanship for the acquired device is given in the 

current terms and conditions.

Here you will find our current terms and conditions.

https://www.keb.de/de/agb.html

Further agreements or specifications require a written confirmation.

Support

Through multiple applications not every imaginable case has been taken into ac-

count. If you require further information or if problems occur which are not treated de-

tailed in the documentation, you can request the necessary information via the local 

KEB Automation KG agency.

The use of our units in the target products is beyond of our control and therefore 

exclusively the responsibility of the machine manufacturer, system integrator or 

customer.

The information contained in the technical documentation, as well as any user-specific 

advice in spoken and written and through tests, are made to best of our knowledge and 

information about the application. However, they are considered for information only 

without responsibility. This also applies to any violation of industrial property rights of a 

third-party.
Selection of our units in view of their suitability for the intended use must be done gener-

ally by the user. 

Tests can only be done within the application by the machine manufacturer. They 

must be repeated, even if only parts of hardware, software or the unit adjustment 

are modified. 

Copyright

The customer may use the instruction manual as well as further documents or parts 

from it for internal purposes. Copyrights are with KEB Automation KG and remain valid 

in its entirety.
Other wordmarks or/and logos are trademarks (™) or registered trademarks (®) of their 

respective owners and are listed in the footnote on the first occurrence.

Summary of Contents for ACOMBIVERT F5 X3A

Page 1: ...C O M B I V E R T Instructions For Use COMBIVERT F5 Encoder Interface Channel 1 SIN COS Channel 2 variable Translation of the original manual Document Part Version 20145744 GBR 00...

Page 2: ...2...

Page 3: ...on observance of this safety instruction WARNING Dangerous situation which may cause death or serious injury in case of non observance of this safety instruction CAUTION Dangerous situation which may...

Page 4: ...the target products is beyond of our control and therefore exclusively the responsibility of the machine manufacturer system integrator or customer The information contained in the technical documenta...

Page 5: ...oltage supply 7 3 2 Channel 1 8 3 2 1 Specifications 8 3 2 2 Description of X3A 8 3 2 3 Input signals 8 3 2 3 1 Analog input signals 9 3 2 3 2 Encoder monitoring 10 3 2 4 Connection of the encoder 11...

Page 6: ...instruction comprises the installation of the interface card the connection as well as the start up of a suitable encoder Further information and the parameter adjust ments are described in the applic...

Page 7: ...nterfaces Uint 24VDC Internal voltage supply of COMBIVERT X2A X3A X3B 5 2V 24V 5V 24V 5V Uint Uext Iint 120mA at Hiperface Sin Cos EnDat SSI Sin Cos and UVW 170mA at all other encoder interfaces Uext...

Page 8: ...Absolute track for initial position and angular calculation 7 D Absolute track for initial position and angular calculation 8 A Incremental encoder input track A for counter and direction detection 9...

Page 9: ...absolute track C and D will be compared with the position any 30ms Since the absolute track is relatively inaccurate corrections are only made until a valid zero signal is recognized Then only an erro...

Page 10: ...The absolute track is monitored approx all 30 ms and the incremental track is monitored ap prox all 16 ms If the permissible signal levels are fallen below Error Encoder 1 value 32 is triggered Depend...

Page 11: ...ne side to COM Do not connect exterior and interior shielding Figure 3 3 4 1 Connection of the encoder Motor encoder plug Socket X3A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 5 4 3 2 1 10 9 8 7 6 15 1...

Page 12: ...he value is calculated as follows Encoder line length U Umin Imax 2 R max encoder current Imax see encoder description Supply voltage U 5 2V minimum input voltage Umin see encoder description KEB enco...

Page 13: ...being transferred encoder and interface are working The following status messages triggers Error Encoder Change E EncC because the correct evaluation of the position is no longer guaranteed Error E E...

Page 14: ...ng on the respective memory structure 96 New value detected because an another encoder is attached 98 Interface is busy The following status messages triggers Error Encoder 1 E Enc1 if encoder data is...

Page 15: ...Notices GB 15...

Page 16: ...Tel 44 1933 402220 Fax 44 1933 400724 E Mail info keb co uk Internet www keb co uk ITALIEN KEB Italia S r l Unipersonale Via Newton 2 I 20019 Settimo Milanese Milano Tel 39 02 3353531 Fax 39 02 33500...

Reviews: