background image

Record the Serial number and Model number of this Miraclean

®

 

Electric Griddle in 

the spaces provided. 

Keep these numbers for future reference.

MIRACLEAN

®

 

ELECTRIC GRIDDLE

SERIES 2000

KEEP A COPY OF YOUR BILL OF SALE. 

The date on the bill establishes the warranty period should service be required. 
If service is performed, it is in your interest to obtain and keep all receipts.

Keating commercial griddles are not intended for household use.

As continuous product improvement occurs, specifi cations may be 
changed without notice.

IMPORTANT:

THIS MANUAL PROVIDES SPECIFIC OPERATING INSTRUCTIONS FOR YOUR 
MODEL. USE THE MIRACLEAN® ELECTRIC GRIDDLE ONLY AS INSTRUCTED 
IN THIS MANUAL.

Part # 037401

ElecGriddle2000_2013

06/13

1-800-KEATING  |  keatingofchicago.com

MANUAL

KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL.

SERIAL NUMBER

MODEL NUMBER

Summary of Contents for miraclean 2000 series

Page 1: ...formed it is in your interest to obtain and keep all receipts Keating commercial griddles are not intended for household use As continuous product improvement occurs specifications may be changed with...

Page 2: ...r appliance 9902091 9902091 i Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions...

Page 3: ...rvice personnel Operating information for Keating equipment has been prepared for use by qualified and or authorized personnel Keating equipment is made in the USA and has American sizes of hardware A...

Page 4: ...ment will void the warranty Before uncrating check equipment carefully for damage INSTALLATION Installation must conform with local codes or in absence of local codes with the current National Electri...

Page 5: ...ddle terminal connections to the appropriate wiring diagram for the griddle see pages 12 14 Wiring Diagram to see if the griddle is connected three phase or single phase All wires cords plugs receptac...

Page 6: ...ing MIRACLEAN Griddles are designed to provide maximum production efficiency and deliver high quality food products Follow cooking procedures below 1 For 208 240 Volt Unit Set ON OFF switch to ON posi...

Page 7: ...and how the surface can be damaged Proper use of the utensils supplied with your MIRACLEAN Griddle will prevent surface damage Figure 3 3 NOTE Damage done to the MIRACLEAN surface is irreparable and...

Page 8: ...ur MIRACLEAN Electric Griddle under warranty needs repairs other than routine maintenance or cleaning you are required to contact Keating of Chicago at 1 800 KEATING before calling a local service com...

Page 9: ...e 4 1 rotate dial plate to match thermometer reading and tighten screws NOTE Calibration is not covered under warranty CLEANING Proper care should be taken to fully clean the griddle on a regular basi...

Page 10: ...hough element is heating a Indicating light is faulty a Replace indicating light Temperature of griddle is erratic a Thermostat out of calibration b Thermostat bulb improperly placed c Exhaust problem...

Page 11: ...9521 THERMOSTAT REPLACEMENT KIT 400 F 035954 THERMOSTAT DIAL PLATE 400 F 034870 THERMOSTAT DIAL PLATE 550 F 060105 THERMOSTAT KNOB 400 F BLACK 060612 THERMOSTAT KNOB 550 F BLACK 038368 B LIGHT 050255...

Page 12: ...005913 1 006228 1 006229 1 3 INSULATION BOARD 002489 1 002493 1 002490 1 4 HEATING ELEMENT PAN 020553 1 020554 1 020556 1 5 HEATING ELEMENT BULB HOLD DOWN M BRACKET 008593 1 1 1 6 HEATING ELEMENT HOLD...

Page 13: ...1 800 KEATING ELECTRIC GRIDDLE SERIES 2000 11 ASSEMBLY INSTRUCTIONS FOR GRIDDLE STAND on Casters There is no top on this stand...

Page 14: ...keatingofchicago com 12 208 240 VOLT WIRING DIAGRAM 3 PHASE CONNECTIONS...

Page 15: ...1 800 KEATING ELECTRIC GRIDDLE SERIES 2000 13 208 240 VOLT WIRING DIAGRAM SINGLE PHASE CONNECTIONS...

Page 16: ...keatingofchicago com 14 480 VOLT WIRING DIAGRAM NOTE Griddles rated at 480 Volts use type D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles...

Page 17: ...S 2300W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 36x24 3 ELEMENTS 2300W EACH VOLTS kW AMPS PER LINE THREE PHASE L1...

Page 18: ...4 24 24 41 240 10 7 26 26 26 45 36x30 3 ELEMENTS 3000W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 10 7 34 34 22 52 220 12 0 36 36 24 55 240 14 3 39 39 26 60 42x30 48x30 4 E...

Page 19: ...W AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 13 4 43 43 28 65 220 15 0 45 45 30 68 240 17 9 49 49 32 75 42x36 48x36 4 ELEMENTS 3750W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS...

Page 20: ......

Page 21: ......

Page 22: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...

Reviews: