Keating Of Chicago Instant Recovery 2000 Series Manual Download Page 8

     

keatingofchicago.com

6

(See lighting instructions plate attached to the inner 
door of Keating Gas Fryer.) Model AA does not require 
an electrical connection.

Make sure that the Keating Gas Fryer is plugged in. If 
not your fryer will not operate. Make sure that the main 
gas valve on the gas supply line to the Keating Gas 
Fryer is in the “ON” position.

AIR IN THE GAS SUPPLY LINE MAY REQUIRE A LONGER 
THAN NORMAL PERIOD OF TIME TO LIGHT YOUR FRYER 
DURING INITIAL INSTALLATION OR AFTER OVERNIGHT 
SHUTDOWN.

NOTE:

 Unless you have an AA model your fryer cannot 

be operated during a power failure.

AA MODELS OPERATING INSTRUCTIONS

DO NOT START FRYER WITHOUT FIRST FILLING FRYER 

POT.

START-UP PROCEDURE

1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “OFF” position.
3. Turn gas valve knob to “PILOT” position. 
4. Light constant pilot located on left side of 
    pilot runner tube.
5. Push and hold the gas valve knob for 30 seconds 
    and release.
6. With the pilot still on, turn gas valve knob to the 
    “ON” position. 
7. Set thermostat to desired temperature, turn 
    “MAIN POWER” switch to the “ON” position. 
     The burners will come on.

HI-LIMIT TEST PROCEDURE (Do Bi-monthly):

1. Place a suitable thermometer in the oil on the 
    front left corner of the fryer 2" from the top to 
    check temperature.
2. Set thermostat to 375°F after burners go off. 
    Push and hold the “HIGH LIMIT TEST" switch. 
    The burners will come on.
3. When 425°F is reached the burners go off. Now it 
    is ok to release test switch.
4. If the high limit thermostat does not shut down 
    the burners between 425°- 450°F as read on 
    the thermometer, the high limit must be replaced 
    immediately.
5. To re-start the fryer it must be cooled down to 
    cooking temperature and the red reset button on 
    the high limit thermostat pushed. Return to STEP 3 
    in the start-up procedure.

SHUTDOWN PROCEDURE

1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “OFF” position.
3. Turn gas valve knob to the “OFF” position.
4. Turn gas supply valve to the “OFF” position.
5. Check to make sure all burners and pilot are out. 

BB MODELS OPERATING INSTRUCTIONS

DO NOT START FRYER WITHOUT FIRST FILLING FRYER 

POT.

START-UP PROCEDURE

1. Set “MELT-IDLE-FRY” switch to “IDLE” position 
    and thermostat to the “OFF” position.
2. Turn “MAIN POWER" switch to the “ON” position.
3. Hold the “PUSH TO LIGHT” switch in until the 
    amber “PILOT ON” light comes on. 
4. Set thermostat to desired temperature.
5. Set “MELT-IDLE-FRY” switch to “FRY.” The burners 
    will come on. Select “MELT” with solid shortening 
    until liquid shortening is 1" from full, then switch 
    to the “FRY” position.

HI-LIMIT TEST PROCEDURE - ALL MODELS 
(Do Bi-monthly):

1. Place a suitable thermometer in the oil on the 
    front left corner of the fryer 2" from the top to 
    check temperature.
2. Set thermostat to 375°F after burners go off. 
    Push and hold the “HIGH LIMIT TEST” switch. 
    The burners will come on.
3. When 425°F is reached the burners go off. Now it 
    is ok to release test switch.
4. If the high limit thermostat does not shut down 
    the burners between 425°-450°F as read on 
    the thermometer, the high limit must be replaced 
    immediately.
5. To re-start the fryer it must be cooled down to 
    cooking temperature and the red reset button on 
    the high limit thermostat pushed. Return to STEP 3 
    in the start-up procedure.

SHUTDOWN PROCEDURE

1. Set “MELT-IDLE-FRY” switch to “IDLE” position and 
    thermostat to the “OFF” position.
2. Turn “MAIN POWER" switch to the “OFF” position. 
    Its green light will go off.
3. Check to make sure all burners and pilot are out.

TS MODELS OPERATING INSTRUCTIONS

DO NOT START FRYER WITHOUT FIRST FILLING FRYER 

POT.

START-UP PROCEDURE

1. Set “MELT-IDLE-FRY” switch to “IDLE” position and 
    thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to “ON” position. 
    Its green light and the timers will come on.
3. Light constant pilot located on left side of pilot 
    runner tube. 
4. Hold the “PUSH TO LIGHT” switch for 30 
    seconds. The pilot runner tube will light.

Summary of Contents for Instant Recovery 2000 Series

Page 1: ......

Page 2: ...ACTURER S INSTRUCTIONS THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER...

Page 3: ...tions of any kind to your equipment will void the warranty Before uncrating check equipment carefully for damage IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage...

Page 4: ...portant consider ations for efficient operation of the Keating Gas Fryer It should be installed so that the products of combus tion are removed efficiently without producing drafts that will interfere...

Page 5: ...STERS IT MUST BE INSTALLED WITH CASTERS SUPPLIED A CONNECTOR COMPLYING WITH EITHER ANSI Z21 69 OR CAN CGA 6 16 AND A QUICK DIS CONNECT DEVICE COMPLYING WITH EITHER ANSI Z21 41 OR CSA 6 9 IT MUST ALSO...

Page 6: ...leave your fryer operating unattended When all previous instructions have been completed Check the serial plate on the panel inside cabinet to determine if the burner is set up for the proper type gas...

Page 7: ...E SWITCHING THE FRYER ON IF OIL LEVEL DROPS BELOW TOP OF HEAT TRANSFER TUBES SEVERE DAMAGE TO FRYER AND INJURY TO OPERATOR MAY RESULT WATER IN ANY FORM AND HOT OIL DON T MIX OIL EXPANDS WHEN HEATED TH...

Page 8: ...he OFF position 2 Turn MAIN POWER switch to the OFF position 3 Turn gas valve knob to the OFF position 4 Turn gas supply valve to the OFF position 5 Check to make sure all burners and pilot are out BB...

Page 9: ...designed to provide maximum production efficiency and deliver high quality food products Low temperature cooking highly polished stainless steel and a true COLD ZONE mean extended oil life Follow the...

Page 10: ...show StO for ap proximately two seconds and the timer will return to normal operation Repeat the process as necessary for the other timers OPERATING LOGIC When the timer is powered up the display will...

Page 11: ...CLE CLEANING AND BOIL OUT FOR A SINGLE FRYER When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition Keating Sea Powder dissolves any gr...

Page 12: ...ETTING MOTOR TO PREVENT SERIOUS INJURY WHEN RESET SWITCH IS ENGAGED SEE FILTER MANUAL 16 Check thermostat bulb positioning see page 12 17 Refill the fryer with new or filtered oil FOR A FRYER WITH ATT...

Page 13: ...d damaging the fryer do not power wash spray or hose it down while cleaning it 17 Pump must be primed with oil after boil out with water FAILURE TO LUBRICATE PUMP MAY CAUSE SEVERE DAMAGE TO FILTER SYS...

Page 14: ...meter in same position for every calibration 4 If calibration of fryer is found to be less than 25 F off simply loosen four dial plate retaining screws rotate dial plate to match thermometer reading a...

Page 15: ...pression fitting snugly into fryer vessel 5 Adjust bulb so at least 2 of bent portion of it is next to heat transfer tube and tighten compression nut onto compression fitting for fryer 10x11 18 up The...

Page 16: ...uct overloaded in fryer vessel c Oil is breaking down and foaming d Water in cold zone a Fill fryer up to Fill Level line as oil expands when heated b Follow recommended cooking production figures in...

Page 17: ...plates are damaged or lost replace them immediately B C A D E BACK PANEL F PARTS LIST GAS FRYER CONTROL PANEL AA GAS ITEM QTY DESCRIPTION P N A 1 THERMOSTAT DIAL PLATE 375 058037 B 1 THERMOSTAT KNOB...

Page 18: ...CKER WHITE MOMENTARY 032297 Push to Light Hi Limit Test G 1 SWITCH MELT IDLE FRY 032829 H 1 INDICATING LIGHT GREEN 021255 I 1 INDICATING LIGHT RED 021209 J 1 HIGH LIMIT Resettable 034357 K 1 FLAME SWI...

Page 19: ...016341 E 1 RUNNER PILOT TUBE ASSEMBLY 019408 F 1 GAS VALVE NATURAL 023625 LP 023624 POT ASSEMBLY 14AA GAS F A B C D E ITEM QTY DESCRIPTION P N A 3 3 FIN RADIANT 000041 B 1 POT WELDMENT 14 GAS UNI POT...

Page 20: ...F 1 GAS VALVE NATURAL Front Drain TS 037237 LP Front Drain TS 037238 NATURAL Rear Drain TS 037241 1 LP Rear Drain TS 037242 1 NATURAL All BB Models 037227 1 LP All BB Models 037228 ITEM QTY DESCRIPTIO...

Page 21: ...1 800 KEATING GAS FRYER SERIES 2000 19 WIRING DIAGRAMS AA 2000 ELECTRICAL ASSEMBLY BB 2000 ELECTRICAL ASSEMBLY...

Page 22: ...keatingofchicago com 20 TS 2000 ELECTRICAL ASSEMBLY not shown to scale BB ELECTRICAL ASSEMBLY WITH SAFE AND EASY FILTER not shown to scale...

Page 23: ...1 800 KEATING GAS FRYER SERIES 2000 21 TS ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER BASKET LIFT ELECTRICAL ASSEMBLY ALL FRYERS...

Page 24: ...nty against latent defects Exclusions The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Page 25: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...

Reviews: