Keating Of Chicago Instant Recovery 2000 Series Manual Download Page 13

1-800-KEATING

 

|

   

GAS FRYER - SERIES 2000

UNDER NO CIRCUMSTANCES SHOULD THE FRYER 
BE LEFT UNATTENDED DURING BOIL-OUT. TRAINED 
PERSONNEL MUST BE PRESENT DURING THE 
PROCEDURE TO PREVENT BOIL OVER OR TO TURN 
OFF THE POWER IF WATER DROPS BELOW HEAT 
TRANSFER TUBES.

10. Dissolve 2/3 cup of Keating Sea Powder for 
every fi ve gallons of water and let soak for 1/2 hour. 
If there is a large build-up of carbonized grease, 
allow fryer to soak overnight.

11. While soaking, a natural fi ber brush may be 
used to scrub the tubes and inside walls of fryer. 
Pump the water and Sea Powder into a dry suitable 
receptacle and remove from cooking area. Sprinkle 
Keating Klenzer liberally on tubes and sides of fryer 
vessel. A non-abrasive scouring pad may be used to 
remove the now softened carbonized grease. 

Thoroughly rinse fryer vessel with potable water to 
remove all Klenzer. Prior to refi lling with oil, wipe the 
inside of the fryer vessel making sure all water and 
Klenzer have been removed.

DO NOT DAMAGE OR REPOSITION THERMOSTAT 
PROBE AS THIS MAY AFFECT THE ACCURACY OF 
THE FRYER.

WATER IN ANY FORM AND HOT OIL DON'T MIX!

12. Close the drain valve and disconnect the clean-
ing hose.

13. Check thermostat bulb positioning (should be 1 
paper thickness away from heat tube).

14. Refi ll the fryer with new or fi ltered oil. Wait until 
fi lter drawer is cool before cleaning, approximately 
15 minutes.

15. Remove fi lter drawer, drain, clean and dry.

16. Prepare fi lter drawer and return to fi lter cabinet.

To avoid damaging the fryer, do not power wash, 
spray or hose it down while cleaning it.

17. Pump must be primed with oil after boil-out with 
water.

FAILURE TO LUBRICATE PUMP MAY CAUSE SEVERE 
DAMAGE TO FILTER SYSTEM.

SELF HELP GUIDE

Before calling for service, review this list. It may save 
you both time and expense. This list includes common 
occurrences that are not the result of defective work-
manship or materials in this appliance.

PROBLEM

SOLUTION

Fryer does not  
operate

• Check power cord, unit plugged in?

• Thermostat is in the OFF position. 

• Check gas supply.

• See fi gure below.

• Reset high limit.

NOTE: 

For a fryer with a Central, Zero-Space™ Filter, or 

Safe & Easy Filter always check the rear drain operat-
ing handle before attempting to use the fryer. A safety 
switch prevents the fryer from operating if the handle 
is not pushed in completely and latched. (See fi gure 5)

NOTE:

 For safety purposes, all Hi-Limit controls are 

manually reset. Always check the Hi-Limit reset button 
before attempting to use the fryer. If the Hi-Limit has 
tripped, the fryer will not operate. (Located behind the 
fryer door underneath the front panel).

WARRANTY REPAIRS

Keating’s warranty begins with the date of installation. 
In the event that your Instant Recovery® Fryer, under 
warranty, needs repairs other than routine cleaning, 
you are requested to contact KEATING OF CHICAGO, 
INC. (1-800 KEATING).

Figure 5

Rear Drain Operating Handle

PREVENTIVE MAINTENANCE

Preventive maintenance should be done in daily, week-
ly, monthly and yearly intervals as necessary. Following 
preventive maintenance procedures will help keep your 
fryer working effi ciently. Proper care and servicing will 
lead to years of quality performance.

11

Summary of Contents for Instant Recovery 2000 Series

Page 1: ......

Page 2: ...ACTURER S INSTRUCTIONS THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER...

Page 3: ...tions of any kind to your equipment will void the warranty Before uncrating check equipment carefully for damage IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage...

Page 4: ...portant consider ations for efficient operation of the Keating Gas Fryer It should be installed so that the products of combus tion are removed efficiently without producing drafts that will interfere...

Page 5: ...STERS IT MUST BE INSTALLED WITH CASTERS SUPPLIED A CONNECTOR COMPLYING WITH EITHER ANSI Z21 69 OR CAN CGA 6 16 AND A QUICK DIS CONNECT DEVICE COMPLYING WITH EITHER ANSI Z21 41 OR CSA 6 9 IT MUST ALSO...

Page 6: ...leave your fryer operating unattended When all previous instructions have been completed Check the serial plate on the panel inside cabinet to determine if the burner is set up for the proper type gas...

Page 7: ...E SWITCHING THE FRYER ON IF OIL LEVEL DROPS BELOW TOP OF HEAT TRANSFER TUBES SEVERE DAMAGE TO FRYER AND INJURY TO OPERATOR MAY RESULT WATER IN ANY FORM AND HOT OIL DON T MIX OIL EXPANDS WHEN HEATED TH...

Page 8: ...he OFF position 2 Turn MAIN POWER switch to the OFF position 3 Turn gas valve knob to the OFF position 4 Turn gas supply valve to the OFF position 5 Check to make sure all burners and pilot are out BB...

Page 9: ...designed to provide maximum production efficiency and deliver high quality food products Low temperature cooking highly polished stainless steel and a true COLD ZONE mean extended oil life Follow the...

Page 10: ...show StO for ap proximately two seconds and the timer will return to normal operation Repeat the process as necessary for the other timers OPERATING LOGIC When the timer is powered up the display will...

Page 11: ...CLE CLEANING AND BOIL OUT FOR A SINGLE FRYER When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition Keating Sea Powder dissolves any gr...

Page 12: ...ETTING MOTOR TO PREVENT SERIOUS INJURY WHEN RESET SWITCH IS ENGAGED SEE FILTER MANUAL 16 Check thermostat bulb positioning see page 12 17 Refill the fryer with new or filtered oil FOR A FRYER WITH ATT...

Page 13: ...d damaging the fryer do not power wash spray or hose it down while cleaning it 17 Pump must be primed with oil after boil out with water FAILURE TO LUBRICATE PUMP MAY CAUSE SEVERE DAMAGE TO FILTER SYS...

Page 14: ...meter in same position for every calibration 4 If calibration of fryer is found to be less than 25 F off simply loosen four dial plate retaining screws rotate dial plate to match thermometer reading a...

Page 15: ...pression fitting snugly into fryer vessel 5 Adjust bulb so at least 2 of bent portion of it is next to heat transfer tube and tighten compression nut onto compression fitting for fryer 10x11 18 up The...

Page 16: ...uct overloaded in fryer vessel c Oil is breaking down and foaming d Water in cold zone a Fill fryer up to Fill Level line as oil expands when heated b Follow recommended cooking production figures in...

Page 17: ...plates are damaged or lost replace them immediately B C A D E BACK PANEL F PARTS LIST GAS FRYER CONTROL PANEL AA GAS ITEM QTY DESCRIPTION P N A 1 THERMOSTAT DIAL PLATE 375 058037 B 1 THERMOSTAT KNOB...

Page 18: ...CKER WHITE MOMENTARY 032297 Push to Light Hi Limit Test G 1 SWITCH MELT IDLE FRY 032829 H 1 INDICATING LIGHT GREEN 021255 I 1 INDICATING LIGHT RED 021209 J 1 HIGH LIMIT Resettable 034357 K 1 FLAME SWI...

Page 19: ...016341 E 1 RUNNER PILOT TUBE ASSEMBLY 019408 F 1 GAS VALVE NATURAL 023625 LP 023624 POT ASSEMBLY 14AA GAS F A B C D E ITEM QTY DESCRIPTION P N A 3 3 FIN RADIANT 000041 B 1 POT WELDMENT 14 GAS UNI POT...

Page 20: ...F 1 GAS VALVE NATURAL Front Drain TS 037237 LP Front Drain TS 037238 NATURAL Rear Drain TS 037241 1 LP Rear Drain TS 037242 1 NATURAL All BB Models 037227 1 LP All BB Models 037228 ITEM QTY DESCRIPTIO...

Page 21: ...1 800 KEATING GAS FRYER SERIES 2000 19 WIRING DIAGRAMS AA 2000 ELECTRICAL ASSEMBLY BB 2000 ELECTRICAL ASSEMBLY...

Page 22: ...keatingofchicago com 20 TS 2000 ELECTRICAL ASSEMBLY not shown to scale BB ELECTRICAL ASSEMBLY WITH SAFE AND EASY FILTER not shown to scale...

Page 23: ...1 800 KEATING GAS FRYER SERIES 2000 21 TS ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER BASKET LIFT ELECTRICAL ASSEMBLY ALL FRYERS...

Page 24: ...nty against latent defects Exclusions The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or main...

Page 25: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...

Reviews: