Q.5.42 June 2018
Page 5
© Copyright 2018 KE2 Therm Solutions, Inc., Washington, Missouri 63090
KE2 Local Area
Dashboard & Alarms
Overview, Installation, and Setup Instructions
Using the KE2 Flash Drive for Data Logging
the KE2 LDA
(See bulletin Q.5.48 for more on the KE2 Flash Drive)
Connect customer
Network to WAN
WAN
Power
LAN
.
KE2
Evaporator
Efficiency
TM
therm
solutions
ENTER
MODIFY
STATUS
ABC Contracting
(888)555-3358
All Clear
Compressor
On
System Mode
Cool
Evaporator Fan
Off
Room Temp
-8.5 F
Coil Temp
15.4 F
Sat Temp
46.0 F
Superheat
0.0 F
Valve Position
Manual
Suct Pressure
96.2 F
Suct Temp
87.7 F
Dig Input 3
Dis
Defrost
Off
Aux Temp
Dis
Dig Input 1
Closed
Dig Input 2
Dis
KE2
Evaporator
Efficiency
TM
therm
solutions
ENTER
BACK
.
Ethernet Controllers:
KE2 Evaporator Efficiency,
KE2 Evap for Rack Efficiency,
KE2 Controlled Environment
USB Hub
KE2 Flash
Drive
For data logging up to 10
Ethernet or Serial-Modbus controllers
Serial-Modbus Controllers:
KE2 Temp, KE2 Low Temp, KE2 Adaptive Control
.
Hold for manual defrost
therm
solutions
KE2
Temp
Hold for manual defrost
therm
solutions
KE2
Temp
.
A
B
Regardless of how the KE2 LDA is connect-
ed to the network
(as illustrated in Options
1 through 5)
, if the KE2 Flash Drive is used
for data logging, the USB Hub is connect-
ed first. Then the KE2 Flash Drive, and the
daisy-chained Serial-ModBus controllers,
are connected to the ports in the USB Hub.
KE2 Flash Drive Kit
(pn 21146)
KE2 Flash Drive
USB Hub
Installing the KE2 LDA: Option 6
Wirelessly Tether to Customer WiFi
EACH DEVICE MUST HAVE A SEPARATE/
UNIQUE MODBUS ADDRESS
(See Appendix B for instructions)
Connect Customer
Network
Plug power cable into the KE2 LDA
and the other end into an electrical outlet.
The unit will power on automatically.
WAN
Power
LAN
.
KE2
Evaporator
Efficiency
TM
therm
solutions
ENTER
BACK
.
MODIFY
STATUS
ABC Contracting
(888)555-3358
All Clear
Compressor
On
System Mode
Cool
Evaporator Fan
Off
Room Temp
-8.5 F
Coil Temp
15.4 F
Sat Temp
46.0 F
Superheat
0.0 F
Valve Position
Manual
Suct Pressure
96.2 F
Suct Temp
87.7 F
Dig Input 3
Dis
Defrost
Off
Aux Temp
Dis
Dig Input 1
Closed
Dig Input 2
Dis
KE2
Evaporator
Efficiency
TM
therm
solutions
ENTER
BACK
.
Ethernet Controllers:
KE2 Evaporator Efficiency,
KE2 Evap for Rack Efficiency,
KE2 Controlled Environment
NOTE: DHCP or Static IP in
Customer Network
Serial-Modbus Controllers:
KE2 Temp, KE2 Low Temp, KE2 Adaptive Control
.
Hold for manual defrost
therm
solutions
KE2
Temp
Hold for manual defrost
therm
solutions
KE2
Temp
.
A
B