© Copyright 2019 KE2 Therm Solutions, Inc., Washington, Missouri 63090
Q.1.45
May 2019
KE2 Evap
OEM
pn21231
Quick Start Guide
This reference should remain on site with the installed KE2 Evap OEM controller.
Get your controller
online, & benefit from remote
monitoring, control, and text /
e-mail alarm notices.
Just a few easy steps, with
KE2 Smart Access
Pressure Transducer
Part #
Description
Lead
Length
20201
Pressure Transducer – 0 to 150 psia
10 ft.
20204
Pressure Transducer - 0 to 150 psia
40 ft.
KE2 Therm Accessories
Remote Displays
Part #
Description
21232
KE2 Basic (Remote) Display w/ 15 ft. cable
21324
Snap track - 12”
21320
KE2 Combo Display (no accessories included)
21786
Combo Display - 25 ft. Cable
21320
Combo Display - Junction Box
21781
9V Rechargeable Battery for Combo Display
Temperature Sensors
Part #
Description
Lead
Length
21151
Temperature Sensor Pack - 3-colors
15 ft.
21066
Temperature Sensor Pack - 3-colors
40 ft.
20199
Temperature Sensor - Black
10 ft.
20200
Temperature Sensor - Black
40 ft.
21795
Temperature Sensor - Yellow
10 ft.
21793
Temperature Sensor - Green
10 ft.
21794
Temperature Sensor - Blue
10 ft.
RSV - Refrigeration Stepper Valves
Valve Body
Part #
Connections - Inches ODF
Inlet x Outlet
Lead
Length
RSV-100
21667
3/8 x 1/2
5 ft.
RSV-100
21665
3/8 x 1/2
10 ft.
RSV-100
21666
3/8 x 1/2
40 ft.
RSV-130
21169
3/8 x 1/2
5 ft.
RSV-130
21161
3/8 x 1/2
10 ft.
RSV-130
21162
3/8 x 1/2
40 ft.
RSV-220
21170
3/8 x 1/2
5 ft.
RSV-220
21163
3/8 x 1/2
10 ft.
RSV-220
21164
3/8 x 1/2
40 ft.
RSV-320
21171
3/8 x 1/2
5 ft.
RSV-320
21165
3/8 x 1/2
10 ft.
RSV-320
21166
3/8 x 1/2
40 ft.
RSV-320
21172
1/2 x 1/2
5 ft.
RSV-320
21167
1/2 x 1/2
10 ft.
RSV-320
21168
1/2 x 1/2
40 ft.
RSV-400
21529
5/8 x 7/8
15 ft.
RSV-400
21530
5/8 x 7/8
40 ft.
RSV-550
21594
5/8 x 7/8
15 ft.
RSV-550
21595
5/8 x 7/8
40 ft.
RSV-650
21779
5/8 x 7/8
15 ft.
RSV-650
21778
5/8 x 7/8
40 ft.
RSV-C10 Stator
21149
For RSV-100 to 320
10 ft.
RSV-C40 Stator
21150
For RSV-100 to 320
40 ft.
RSV-LC15 Stator
21525
For RSV-400 to 650
15 ft.
RSV-LC40 Stator
21526
For RSV-400 to 650
40 ft.
Contents
Point to Point Wiring Diagram
Controller with KE2 Terminal Board
Page 2
Wiring Diagram
Controller without Terminal Board
Page 3
Coil Sensor Location
Page 4
Navigation Using the Basic Display
Page 5
User Interface/Controller Setup
Page 5
Menus and Parameters
Basic Setpoints Menu
Page 6
Advanced Setpoints Menu
Page 6 -7
Types of Control - First Time Setup Menu
Page 8
System Modes
Page 8
Auxiliary Input Modes
Page 8
Variables Menu
Page 8
Refrigerants
Page 8
Valve Types
Page 8
Alarm Status Menu
Page 9
Alphabetical List of Abbreviations
Page 9 -11
KE2 Smart Access
Page 12
Specifications
Controller
Input Voltage:
100VAC - 240VAC
Ambient Temp:
-40°F to 140°F (-40°C to 60°C)
Operating Temp: -40°F to 140°F (-40°C to 60°C)
Inputs:
(3) temperature sensor
(3) multi-use (temp sensor or digital input)
(1) pressure sensor input
Valve Types:
unipolar and bipolar stepper motors (12V)
Relays:
1-20A resistive (defrost)
(2) 10A inductive
Auxiliary Input 1: room temp, coil temp, monitor, 2nd temp setpoint, door
switch, external alarm, system off, defrost interlock, de-
frost lockout
Auxiliary Input 2:
Auxiliary Input 3:
Communication: Standard TCP/IP
Pressure Transducer
Pressure Range:
0 to 150 psia
Proof Pressure:
450 psi
Burst Pressure:
1500 psi
Operating Temp: -40°F to 275°F (-40°C to 135°C)
Temperature Sensor
Sensor Specs:
-60°F to 150°F (-51°C to 65°C) moisture resistant package