4    Intended use and installation location

The product is designed to protect against solar radiation and possibly to limit reverberation in the space below it.

Users of the product must be adults.

Improper use of the product shall release the Manufacturer from any liability from damage or injuries which might 

result.

Failure to respect the indicated conditions of use shall invalidate any and all warranties provided by the 

manufacturer.

The product, once installed, is intended only to perform raising or lowering of the fabric in order to reach the 

maximum opening and closing positions, as well as the intermediate ones if required.

· Before making the product operational, read Cap.2 “Safety”, pag.23 and Cap.4 “Intended use and 

installation location”, pag.26 carefully.

· Ensure there is nobody obstructing or excessively close to the product’s moving parts when opening 

and closing.

·  Pay  attention  to  all  the  warnings  applied  to  the  product,  and  follow  all  safety  regulations  and 

instructions for use.

· Any use other than those indicated above is forbidden, as different conditions of use could create 

risks to the user and other persons nearby.

· It is strictly prohibited to climb on or hang/place any objects from/on the product.

· The product must always be opened from top to bottom and never vice versa, as it could break with 

the risk of serious personal injuries.

· Close the product completely in the event bad weather or snow.

· The operation of the product with snow on the fabric or in freezing temperatures could damage it.

·  The  formation  of  condensation  on  the  fabric  should  not  be  considered  a  defect;  it  is  a  natural 

phenomenon.

Manual product

The product is opened and closed by a rod attached to a manual crank.

Motorized product 

The product can be opened and closed via:

· a SWITCH installed near the product in a position providing the user full visibility of the same during its movement. 

If installed outdoors, the switch must have appropriate ingress protection.

· A REMOTE CONTROL, portable or wall mounted.

The minimum installation height of the product should comply with applicable legislation; if fitted, the opening/

closing switch must be installed in a protected position, at a minimum, legal height from the ground and in an area 

which is not dangerous to access.

Fig. 6 

OPENING: Fabric stretched 

to its maximum extension. 

Fig. 7 

STOP: Stop of the move

-

ment. 

Fig. 8 

CLOSURE: Fabric wrapped 

around roller tube. 

See the instructions provided in the remote control manual annexed.

Summary of Contents for Italia

Page 1: ...Italia Use and maintenance manual Rev 02 15 12 2017...

Page 2: ...5 3 1 Components 5 4 Intended use and installation location 6 5 Maintenance 8 5 1 Troubleshooting Table 8 5 2 Cleaning 9 5 3 Scheduled maintenance 9 5 4 Extraordinary maintenance 9 6 Technical data 1...

Page 3: ...inary maintenance must only be performed by technicians trained and specialised for those tasks Contact Technical Support Do not place objects on the awning fabric It is forbidden for people to hang o...

Page 4: ...12 2017 rev 02 Italia Use and maintenance manual ALL MEASUREMENTS ARE GIVEN IN MILLIMETRES UNLESS OTHERWISE INDICATED Some figures could be of a general nature and not be referred to the product at i...

Page 5: ...al pag 31 3 1 Components The awning is composed of a metal structure and a fabric screen Metal structure this represents the supporting frame containing the various mechanisms required to open and clo...

Page 6: ...user and other persons nearby It is strictly prohibited to climb on or hang place any objects from on the product The product must always be opened from top to bottom and never vice versa as it could...

Page 7: ...as the system has an IP rating of IP55 or higher The space made available during the installation must take into account the space required for the movement and allow the product to open fully No ladd...

Page 8: ...y forms cone Structure out of square Contact Technical Support Gust of wind Unroll the fabric and eliminate any folds Squeaking noise during movement of the product Impurities obstructions in moving p...

Page 9: ...oth and a spray with PTFE teflon Qualified personnel are not required for ordinary maintenance operations The operations described below will keep the product in good condition if they are performed a...

Page 10: ...is The maximum load permitted for non retractable parts is 800 Pa 6 2 Technical label The technical label which is on the inside cover of this manual specifies the year in which the CE marking the man...

Page 11: ...vide on request only in motorized models WIND SENSOR automatically closes the awning in the event of strong wind The set point for the wind sensor anemometer operation is recorded during the first sta...

Page 12: ...SOL 445 Bellvale Road Chester NY 10918 T 1 888 378 2765 F 1 845 692 1101 www keoutdoordesign us GENNIUS FRANCE sas Quartier Des 4 Chemins Zac Ducournau 83340 Flassans Sur Issole T 33 04 94781773 F 33...

Reviews: