Introduction

DISTRIBUTION AMPLIFIERS

Tech Support: Toll Free USA/Canada 888-258-2028  [email protected]

Customer Support: 718-796-7178 Ext. 23 [email protected]

STEP A2:  

Set the internal DIP switches to match the Configuration Mode

you need for your application.

•  Remove the front panel using a screwdriver, and find the six 8-bit DIP

Switches.  Be sure to configure the six 8-bit DIP Switches as shown in the table

below for either the ADA4 or PCMD4 Mode:

STEP B: 

Connect your KD-ADA4 HD View4 Distribution Amplifier to your

Input and Output sources.

NOTE:  Do not attempt to connect power to the unit during the
cable hook-up.

STEP B1:

Based on your configuration selection, be sure to set the DIP

Switches as described in STEPS A.  Use color-coded RCA cables to con-
nect the Inputs and Outputs to the back of the KD-ADA4 HD View4 unit.
Output runs should not exceed 1000 feet.  Each run of YPrPb cable MUST
be of equal length per Output Group.

STEP B2:  

For the ADA4 Mode where less than four video outputs are

distributed, be sure to use the 75 Ohm terminator (supplied) to terminate
either Y, Pr, or Pb of the first unused Output Group.  For example, if dis-
tributing with only Output Groups 1 and 2, then place the terminator on Y,
Pr, or Pb of Output Group 3.  You should use the Output Groups in
sequential order.

STEP C: 

Apply power to the unit:

•  Use ONLY the external wall-plug power supply provided with your unit, 110-
240V AC, 50-60 Hz, 0.9 Amps
•  Connect the 5-pin DIN external power supply connector to your unit, and plug
the power supply into a power outle

SW1

SW2

SW3

SW4

SW5

SW8

BIT ADA4 PCMD4 ADA4 PCMD4 ADA4 PCMD4 ADA4 PCMD4 ADA4 PCMD4 ADA4 PCMD4

1

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

ON

ON

OFF

2

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

OFF

OFF

ON

3

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

ON

OFF

ON

4

OFF

OFF

ON

OFF

OFF

ON

ON

OFF

ON

OFF

ON

OFF

5

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

ON

OFF

6

OFF

ON

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

7

OFF

ON

ON

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

ON

8

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

Summary of Contents for HD View4

Page 1: ...ents Manual for HD View4 DISTRIBUTION AMPLIFIERS 4 Channel Component Video YPrPb and Left Right analog audio Composite Video and PCM digital audio up to 24 channels Distribution Amplifier with 16 adju...

Page 2: ...rnal DIP switch control whereby you can distribute only Composite Video CV or digi tal PCM audio inputs to as many as 24 destinations DISTRIBUTION AMPLIFIERS Tech Support Toll Free USA Canada 888 258...

Page 3: ...D DA6 or KD CDA12 DA s to drive as many outputs as desired from one source Can drive equal length video cables up to 1000 feet each Sales Support 718 796 7178 Ext 10 Michael keydigital com Marketing S...

Page 4: ...DA4 HD View4 Distribution Amplifier NOTE Do not attempt to connect power to the unit during any of the configuration steps STEP A1 Determine your configuration requirements The KD ADA4 HD View4 has an...

Page 5: ...shown Typical PCMD4 Mode applications Distribution of your single digital PCM audio input to as many as 24 separate destinations In this case the Input Connector Group would be used as shown And each...

Page 6: ...b cable MUST be of equal length per Output Group STEP B2 For the ADA4 Mode where less than four video outputs are distributed be sure to use the 75 Ohm terminator supplied to terminate either Y Pr or...

Page 7: ...4 unit This measurement is from the center point of the RCA jack to the outside of the RCA jack Make note of this resistance value called Rload STEP D2 Determine the resistance of the KD ADA4 HD View4...

Page 8: ...Enclosure type Metal Input Power External power supply provided 110 240V AC 50 60 Hz 0 9A Signal Properties All known video formats are accepted Output scanning format is always the SAME as the input...

Reviews: