30.040
–
Portable Winch - Manual
5
The counter system
7
The counter wheel has three inductive sensors.
8
Every revolution of the counter wheel is equal to 33
cm (1 ft.) of wire length. For measuring the length
in m, the read-out must be divided by 3. An
example: Read-out of 144 indicates a length of
48 m.
The counter does not have a reverse counting
function so the count increases regardless of the
wire
’
s direction.
Push the small button to reset the counter to 0.
The counter has an internal Lithium battery with a
battery life up to 7 years.
Maintenance
9
A bearing housing is located on left and right side of
the winch.
Grease at the least every 6 months or as required.