- 20 -
EN
7.
ADDITIONAL INFORMATION
7.1.
UTENSILS THAT MAY BE USED WITH THE INDUCTION EQUIPMENT:
•
Steel
•
Cast iron
•
Enameled iron
•
Stainless steel marked with
•
The cookware should have a lat bottom (not for the wok appliance) with the dimensions of 12 to 28
cm (stove)û 12 to 32 cm for the model 773025 and up to 38 cm for the model 773028
•
Dishes to the kitchen WOK must be matched to the shape of the shape of the bowl. (WOK type
dishes)
7.2.
UTENSILS THAT MAY NOT BE USED WITH THE INDUCTION EQUIPMENT:
•
Heat-resistant glass
•
Copper
•
Aluminum
•
Ceramic dishes
•
Utensils with a rounded bottom (not for the wok appliance)
•
Utensils with bottom dimensions less than 12 cm (not for the wok appliance).
CAUTION!
Do not move the appliance when the power cord is plugged into an outlet, the temperature of
the glass hobs is above 40°C, or when there are utensils on the hobs.
8.
MAINTENANCE
Daily maintenance
involves the removal of all pots and pans from the device and washing the components
of the cooker using a cloth dampened in water with a dish washing liquid and then wiping them dry with
a clean cloth. Check the condition of the ceramic glass and the knobs and switches on which the knobs
are mounted daily. Detected damage eliminate the glass and/or the entire appliance from service - please
report this problem to the service.
Once a month,
please check whether:
•
the condition of the appliance’s electrical system is correct (the cord is not damagedû the glass does not
show signs of cracksû etc.).
•
all the components of the device are working properly.
Once a year
the device should be inspected by the technical service in order to check the degree of wear
and to identify possible faults of the components and parts of the device.
In case any faults are detectedû they have to be removed by qualiied technical personnel (technical service).
Monthly maintenanceû annual service and repair of the device should only be carried out by qualiied
technical personnel (technical service).
9.
LIST OF ERRORS
Code Description of the error
Solution
L
Surge protectionû supply
voltage is lower than 340V
Check if the power supply is correct; if it isû
the main circuit board is damaged
Need to be
professionally
maintained
H
Surge protectionû supply
voltage is higher than 340V
P
Excessive output powerû
surze protection
Use an ammeter to check if the output
power isn’t too high; if soû reduce the power
of the device.
F
Short-circuit protection of
the induction coil
Check whether the induction coil is
damagedû causing a short-circuit or water
penetration