21
GB-Gas Wok Ring Table
Amicus- Gas-20190619
FR
M
-P
DE
-0
3-
04
(N
YT
/R
&
D/
20
18
10
08
)
Table 7 :
Nominal
Heat Input
Gas Type
Pressure
(mbar)
Nozzle
(mm)
Pilot
Nozzle
(mm)
Primary Air
Adjustment
H (mm)
Secondary Air
Chamber
Air Chamber
for Nozzle
By-pass Screw
for Gas Cock
(mm)
11.5 kW
G30/G31
28-30/37
Ø 1.80
Ø 0.20
12 mm
Opened
Full Opened
Full Opened
Ø 0.95 *
50/50
Ø 1.60
Ø 0.85
13 kW
G20
20
Ø 3.05
Adjusted
5 mm Opened
Full Closed
Full Closed
Adjusted
G25
20
Ø 3.30
25
Ø 3.15
or Adjusted
Reduced Heat Input
Consumption
3.00 kW
G30
0.907 kg/h
G31
0.893 kg/h
G20
1.376 m/h
G20
1.376 m/h
G25
1.600 m/h
WARNING!
After doing conversion please remember to:
- Attach an indelible sticker on technical data plate with the new installation data.
- Fix the new seals on the regulated parts (Primary Air Bushes and Main Injector).
- Take pressure test of gas circuit and check for leaks.
- Properly control Gas Wok Ring Table work according to these instructions.
- Please check main burners’ cross-lighting, stability, and flame factor.
Fig. 8