![KBL megaSun 7900 Alpha Operating Instructions Manual Download Page 47](http://html1.mh-extra.com/html/kbl/megasun-7900-alpha/megasun-7900-alpha_operating-instructions-manual_659417047.webp)
ASSEMBLY NOTE
The contacts of the high-pressure lamp have differ-
ent diameters -> Install in the correct orientation!
Shoulder tanner
PH2
The “x-tra Tan” shoulder tanner
⑱
can
optionally be installed in the place of the
right-hand shoulder part.
⑱
REPLACING THE HIGH-PRESSURE LAMP
Dirt accumulation and bad seating can
lead to damage during the operation.
• Make sure that tanners and high-pressure
lamps are correctly positioned in their respec-
tive holders. Make sure that the contact sur-
faces are clean when you insert the lamp.
• Never touch the lamp or the reflector with
your bare hands. Use a clean, non-greasy
cloth. If necessary, remove grease and dirt
with an alcohol-containing agent.
Attention
The high-pressure lamps must only be
installed and removed by
qualified and
authorised personnel
.
PH2
⑲
⑲
Undo the retaining screw (M6x12) of the
chromium-plated covering.
⇒
Remove the chromium-plated covering.
⑳
⑳
Turn the tanner (approx. 45°) to loosen it from
its holder. Then pull it off carefully.
O p e r a t i n g I n s t r u c t i o n s
|
megaSun 7900
α
47