O p e r a t i n g I n s t r u c t i o n s
|
megaSun 5600
53
Error messages
Faults „Bus Error“, „Bus Relais Error“, „Hardware Error“ and “Aqua low” do not occur with the KBL/5 processor due
to its equipment and processor structure.
Status
message
KBL/4
Status
message
KBL/5
Status description
Remedy
Abluft
(Exhaust air)
Abluft
(Exhaust air)
Bi-metal switch triggers.
Check the air-intake/air-discharge system and the fan.
Let the tanning system cool down and acknowledge
the message by pressing the START button. If the fault
persists, contact your Customer Service.
Maximum
tanning time!
max. time
Incoming enabling signal from coin-box
system longer than approved, i.e. the
value specifi ed under “Maximum tanning
time” (voltage remains connected).
Disconnect the device from the coin-box system.
Aqua low
-
The content of the aquaCool canister
is suffi cient for another 750 spraying
seconds (2.5 operating hours at a cycle
time = 1 minute).
Replace the empty aquaCool canister with a full one. Do
not replace aquaCool with any other liquid. If the canister
is not empty, replace the liquid-level sensor (contact your
Customer Service).
Aqua 0%
-
750 spraying seconds (2.5 operating
hours at a cycle time = 1 minute) have
expired.
Replace the empty aquaCool canister with a full one. Do
not replace aquaCool with any other liquid. If the canister
is not empty, replace the liquid-level sensor (contact your
Customer Service).
Hardware
error
-
Main board defective.
Replace the main board (contact your Customer
Service).
Bus Relais
Error
-
AquaCool Relay board defective.
Replace the AquaCool Relay board (contact your
Customer Service).
E05:BUS:REL
-
I²C bus faulty.
Contact your Customer Service.
E04:BUS:VOICE
-
Communication between control and
Voice-MP3 Player has been interrupted.
1. Check the „Voice“ SD Card.
2. Contact your Customer Service.
E02:BUS:TMP
-
I2C Temperature sensor is faulty or
disturbed.
Contact your Customer Service.