THIS CART IS POWERED BY A SUPER CAPACITOR.  THIS CAPACITOR OR 
CAPACITORS ARE VERY POWERFUL AND SHOULD BE TREATED WITH RESPECT.  

THE LARGE 120-KILOJOULE SIZE IS CAPABLE OF 28,000-WATTS OF POWER.  FOR THIS 

REASON WE ISSUE THE FOLLOWING "WARNING" AND "CAUTION". 
 

WARNING 

 

Eye protection (wear safety glasses) is recommended when performing any procedures with 
or on the capacitor cart 

 

WARNING 

 

DO NOT short circuit the capacitor terminals.  It may be followed by burning or igniting of 

combustible materials adjacent to the point of short circuit.  In case of an accidental short 

circuit it is necessary to disconnect the capacitor immediately from the electrical circuit taking 

relevant safety measures. 
 

WARNING

 

 

DO NOT touch both negative and positive capacitor terminals at the same time.  Serious 
injury may occur. 

 

 

WARNING

 

 

These capacitors contain an electrolyte composed of potassium hydroxide solution.  

Requirements of operation shall be observed to avoid electrolyte leakage.  Electrolyte may 

cause chemical burn if spilled onto unprotected skin.  If the capacitors are destroyed due to 
impact, it is necessary to take actions preventing electrolyte from spilling onto unprotected 

skin of attending personnel.  If bodily contact occurs, flush with water for 15 minutes.  If 

burning persists seek medical attention.  Potassium hydroxide is contained in many 

household drain cleaners. 

 

 

WARNING

 

 

Never attempt to jump start a battery with frozen electrolyte.  A frozen battery could explode 

from applying a charge.  (If battery voltage is less than 2-volts when switch is in battery 

position, check battery prior to proceeding). 

 
 

CAUTION

 

 

Noncompliance with the requirements set forth in this manual may result in capacitor failure.  

Such requirements shall be reviewed prior to and observed in the operation of the cart. 

 

 
 

 

Summary of Contents for KrankingKART

Page 1: ...Professional Jump Start Unit With capacitor power Operation Manual Revision Date 3 12 KOLD BAN INTERNATIONAL LTD 8390 PINGREE ROAD LAKE IN THE HILLS IL 60156 9637 U S A 847 658 8561 FAX 847 658 9280 www koldban com ...

Page 2: ... may occur WARNING These capacitors contain an electrolyte composed of potassium hydroxide solution Requirements of operation shall be observed to avoid electrolyte leakage Electrolyte may cause chemical burn if spilled onto unprotected skin If the capacitors are destroyed due to impact it is necessary to take actions preventing electrolyte from spilling onto unprotected skin of attending personne...

Page 3: ...TABLE OF CONTENTS INTRODUCTION OPERATION MAINTENANCE STORAGE ...

Page 4: ... Pneumatic Tires Auxiliary Charge Switch Optional Wireless Control Following are some parameters for the capacitors used in various carts 12V 24V Nominal Voltage Window 6 5 13 13 26 Max Voltage 14 5 29 Ultimate Maximum Voltage 16 32 Ultimate Minimum Voltage 4 8 Operating Temperature Range 40 to 122 F 40 to 122 F Maximum Power 35kJ 17 5kw 70kJ 26kw 120kJ 35kw The ultimate voltage is not the operati...

Page 5: ...itive battery post and the BLACK cable clamp to the negative battery post or a good ground 4 The cart is wired for polarity protection a buzzer will sound and the LED will be RED if clamps are put on backwards The cart will remain inoperative until the problem is resolved 5 After proper cable hook up is achieved the LED will be GREEN 6 Rock the voltmeter switch to the right This gives you the read...

Page 6: ...or voltage will naturally drop down to 12 volts on a 12 volt unit or drop down to 24 volts on a 24 volt unit in a couple of days if the cart is not used at the green amber band The voltage will hold there for several weeks this is normal The KrankingKART unit will operate sufficiently at this voltage Dead Short Battery The capacitor will discharge very quickly when energized But probably will not ...

Page 7: ...ill be GREEN 6 Rock the voltmeter switch to the right This gives you the reading of the battery voltage of the vehicle to be jump started This also allows the cart to be used 7 Push the Timer Activation Switch to the RESET position to activate timer 8 Get into the vehicle to be started with the Hand held Transmitter 9 Perform the vehicle s normal start procedure Push the button on the Hand held Tr...

Page 8: ...l not harm the dead short battery Battery Cables DO NOT use any other cables than those provided on the KrankingKART The KrankingKART unit is capable of delivering 3000 amps or more in the first few seconds Cart Cables to Short The cable length supplied has been tested to provide maximum capacitor output Adding more length can affect the output delivered It is highly DISCOURAGED to alter the cable...

Page 9: ... this warranty is limited to the repair or replacement of the defective product without charge and KBI shall not be liable for any consequential or incidental damages including labor charges In order to qualify for this warranty the alleged defective product must be returned directly to the KBI factory or authorized Service Center postage or freight prepaid Final determination of defects will be m...

Reviews: