Please view the following illustrations (before servicing)

 

Table.4-1

 

 

 

Troubles

 

Causes

 

 
 
 
 
 
 
 
 
 
 

 

Not a malfunction

 

Outdoor unit

 

Mist or water

 

 

The unit hisses

 

 

FAN  function  stops  automatically  to  defrost  is 
accompanied  by  the  starting  and  stopping 
sound of the solenoid valve.

 

 

At  the  beginning  and  end  of  the  running 
process,  it  sounds  like  water  is  flowing  in  the 
valve for 3-15 minutes due to the dehumidifying 
process of the refrigerant current.

 

 

A  slight  hiss  is  caused  by  heat  exchanger  as 
temperature changes.

 

 

Various foreign matter gets into the unit. 

Switch on the power after a power cut.

 

The  preheating  processes  of  other  equipment 
stops the cooling operation.

 

 

The  user  sets  a  mode  that  conflicts  with  the 
fixed cooling and heating mode.

 

 

FAN mode stops to avoid expelling cold air.

 

 
 
 
 
 
 

 

Indoor unit

 

Bad odor

 

 

Operation light flashes

 

 

No priority or Standby on the panel 
lights up

 

 

 

 

 
 
 
 
 
 
 
 
 
 

Check it again

 

Starts or stops operation automatically

 

Mis-operation of the timer.

 

 
 
 
 

 

Will not run

 

Whether the power is cut.

 

 

Whether the manual power switch is turned on. 

Whether the fuse has melted.

 

Whether the protection device works (operation 
light is on)

 

 

Whether it is the time set.

 

 
 
 
 
 
 
 

Insufficient cooling 

Insufficient heating

 

 

Whether the inlet and outlet of outdoor unit is 
blocked.

 

 

Whether the door and window are open. 

Whether the air filter is blocked by dust. 

Whether the air deflector is in the right place

 

Whether the fan speed is slight or whether it 
is in FAN mode.

 

 

Whether the temperature is set properly.

 

 

Setting COOL and HEAT simultaneously 
(indicator light for Standby or No Priority on 
the panel is on)

 

 
 
 
 

 

 

Owner's manual

 

4

 

Summary of Contents for Amazon IV Pro K2F-252 DN4S

Page 1: ...DN4S K2F 560 DN4S K2F 615 DN4S Thank you for purchasing this air conditioner Before using it please read this manual and keep it for future reference Caution The heating function of an indoor unit is...

Page 2: ......

Page 3: ...rant leaks contact your dealer When the system is installed in a small room keep the refrigerant below the limit otherwise if there s a leak the oxygen in the room may be affected causing a serious ac...

Page 4: ...dren unsupervised 2 PARTS NAMES Fig 2 1 The figure shown above is for reference only and the actual product may be different 1 Air inlet on the left and right sides and at the rear 2 Refrigerant pipe...

Page 5: ...air conditioner is on forced running mode When the protection device is activated the running indicator will light up and the query light will flash Protection device may start under the following cir...

Page 6: ...the fixed cooling and heating mode FAN mode stops to avoid expelling cold air Indoor unit Bad odor Operation light flashes No priority or Standby on the panel lights up Check it again Starts or stops...

Page 7: ...rror Y represents a unit which is not No 0 26 P0 Inverter compressor top Temp protection 27 P1 High pressure protection 28 P2 Low pressure protection ReportsH5afterP2protectionisactivatedthreetimes60m...

Page 8: ...outdoor unit and the low position displays the Qty of indoor units that can communicate with outdoor unit When it s on it will display the rotation frequency of the compressor 2 Operation mode 0 OFF 2...

Page 9: ......

Page 10: ......

Page 11: ...MD13U 018FW DZ 16127000A07798...

Page 12: ......

Reviews: