4. If you set the unit to only respond to the Heating mode, the indoor
unit will run normally if it is running in Heating mode, but it will
display Mode Conflict if it is running in Cooling or Fan mode.

5. If you set the unit to only respond to the Cooling mode, the indoor
unit will run normally if it is running in Cooling or Fan mode, but it will
display Mode Conflict if it is running in Heating mode.

Features of Heating mode

 

●  It takes 3 to 5 minutes for the unit to blow out hot air.

●  The fan motor in the outdoor unit may stop running under high

temperatures.

●  If other indoor units are running in Heating mode, the fan may

stop to prevent expelling hot air.

Defrost in Heating mode

●  In Heating mode, the outdoor unit sometimes frost. To increase

efficiency, the unit will start defrosting automatically (for about
2-10 minutes), and then water will drain out from outdoor unit.

●  During defrosting, both the fan motors in the outdoor unit and

indoor unit will stop running.

Operation conditions

For normal performance, run the air conditioner under the
following temperature conditions:

Table.3-1

 

Protection measures may activate and stop the unit running 
outside of the above conditions.

 

To start the outdoor unit as a minimum the installation must 

have a demand of 10% of the capacity of the outdoor unit.

Protection Device

 

This protection device will stop the unit automatically if the air 
conditioner  is  on  forced  running  mode.  When  the  protection 
device  is  activated,  the  running  indicator  will  light  up  and  the 
query  light  will  flash.  Protection  device  may  start  under  the 
following circumstances:

 

cooling operation:

 

●  The air inlet or air outlet of outdoor unit is blocked.

●  Strong wind continuously blows from the air outlet of the

outdoor unit.

Heating operation:

 

●  Too much dust is trapped in the dust filter in the indoor unit

Power cut

 

●  Power the unit off if there’s a power cut.

●  When power resumes, the indicator on the wire controller

flashes.

●  Push the ON/OFF button again to restart the unit.

Mis-operation

 

In  case  of  a  mis-operation  caused  by  lightning  or  mobile 
wireless  device,  switch  off  the  power  manually.  Push 
ON/OFF again to restart.

 

Heating capacity

 

●  The heating process is to absorb heat from outdoors and

expel heat indoors by the hot pump. Once the outdoor
temperature drops, heating capacity degrades
correspondingly.

●  Use other heating appliances when the outdoor

temperature is low.

●  (See Indoor Unit Operation Manual for detailed

information)

Power the unit off when the protection device starts. Do not 
restart until the problems are solved.

 

4. TROUBLES AND CAUSES

Power of the unit and contact your dealer if the following 
malfunctions occur. Incorrect ON/OFF operation

 

Fuse or leakage protector breaks. 

Foreign matter or water enters in the unit.

 

Owner's manual

 

3

 

Temperature

 

Mode

 

Outdoor 

temperature

 

Indoor 

temperature

 

Room relative 

humidity

 

Cooling mode

 

-5°C ~ 48°C

17°C ~ 32°C

 

below 80%

 

Heating mode

 

(Cooling only type without)

 

-20°C ~ 24°C

≤27°C

 

NOTE 

NOTE

 

CAUTION

 

Summary of Contents for Amazon IV Pro K2F-252 DN4S

Page 1: ...DN4S K2F 560 DN4S K2F 615 DN4S Thank you for purchasing this air conditioner Before using it please read this manual and keep it for future reference Caution The heating function of an indoor unit is...

Page 2: ......

Page 3: ...rant leaks contact your dealer When the system is installed in a small room keep the refrigerant below the limit otherwise if there s a leak the oxygen in the room may be affected causing a serious ac...

Page 4: ...dren unsupervised 2 PARTS NAMES Fig 2 1 The figure shown above is for reference only and the actual product may be different 1 Air inlet on the left and right sides and at the rear 2 Refrigerant pipe...

Page 5: ...air conditioner is on forced running mode When the protection device is activated the running indicator will light up and the query light will flash Protection device may start under the following cir...

Page 6: ...the fixed cooling and heating mode FAN mode stops to avoid expelling cold air Indoor unit Bad odor Operation light flashes No priority or Standby on the panel lights up Check it again Starts or stops...

Page 7: ...rror Y represents a unit which is not No 0 26 P0 Inverter compressor top Temp protection 27 P1 High pressure protection 28 P2 Low pressure protection ReportsH5afterP2protectionisactivatedthreetimes60m...

Page 8: ...outdoor unit and the low position displays the Qty of indoor units that can communicate with outdoor unit When it s on it will display the rotation frequency of the compressor 2 Operation mode 0 OFF 2...

Page 9: ......

Page 10: ......

Page 11: ...MD13U 018FW DZ 16127000A07798...

Page 12: ......

Reviews: