background image

Instructions for use K-ERGOgrip 4944
1 User instructions | 1.4 Transportation and storage

6 / 30

5. Report the damage to KaVo.

6. Consult with KaVo first, before returning a damaged product.

7. Send the signed delivery receipt to KaVo.

If the product is damaged but there was no discernable damage to the packaging

upon delivery, proceed as follows:

1. Report the damage to the shipping company immediately and no later than 7 days

after delivery.

2. Report the damage to KaVo.

3. Leave the product and packaging in the condition in which you received it.

4. Do not use a damaged product.

Note

If the recipient fails to comply with any of the above-mentioned obligations, the

damage will be considered to have arisen after delivery

(in accordance with the General German Freight Forwarders´ Terms and Conditions, Art. 28)

.

Outside Germany

Note

KaVo shall not be held liable for damage arising from transportation.
The shipment must be checked on arrival.

If the packaging is visibly damaged on delivery, please proceed as follows:

1. The recipient of the package must record the loss or damage on the delivery re‐

ceipt. The recipient and the representative of the shipping company must sign this

delivery receipt.

 

Without this evidence, the recipient will not be able to assert a claim for damages

against the shipping company.

2. Leave the product and packaging in the condition in which you received it.

3. Do not use the product.

If the product is damaged but there was no discernable damage to the packaging

upon delivery, proceed as follows:

1. Report any damage to the shipping company either immediately or no later than 7

days after delivery.

2. Leave the product and packaging in the condition in which you received it.

3. Do not use a damaged product.

Note

If the recipient fails to comply with any of the above-mentioned obligations, the

damage will be considered to have arisen after delivery

(in accordance with CMR law, Chapter 5, Art. 30).

1.4.3 Information on the packaging: Storage and transportation

Note

Please keep the packaging in case you need to return the product for servicing or

repair.

The symbols printed on the outside are for transportation and storage, and have the
following meaning:

Summary of Contents for K-ERGOgrip 4944

Page 1: ...Instructions for use K ERGOgrip 4944 Always be on the safe side...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 0 7351 56 0 Fax 49 0 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Page 3: ...y instructions 8 2 2 1 General information 8 2 2 2 Product specific 9 3 Product description 11 3 1 Purpose Intended use 11 3 1 1 General 11 3 2 K ERGOgrip 4944 handpiece 11 3 3 Scope of delivery 12 3...

Page 4: ...nternational Electrotechnical Commission RI Repair instructions RK Retrofitting kit AS Assembly set EP Enclosed parts EMC Electromagnetic compatibility PI Processing instructions 1 1 2 Symbols Importa...

Page 5: ...nty expires if defects or their consequences could possibly have arisen be cause the product has been modified or changed Warranty claims can only be asser ted when they are immediately reported to Ka...

Page 6: ...e proceed as follows 1 The recipient of the package must record the loss or damage on the delivery re ceipt The recipient and the representative of the shipping company must sign this delivery receipt...

Page 7: ...4944 1 User instructions 1 4 Transportation and storage Transport upright with the arrows pointing upwards Fragile protect against impact Protect from moisture Permissible stacking load Temperature r...

Page 8: ...ed in this docu ment to prevent personal and property damage CAUTION CAUTION indicates a hazardous situation that can cause damage to property or mild to moder ate injuries WARNING WARNING indicates a...

Page 9: ...ion of the unit Repair and servicing work on the electronic part of the unit may be done only by skilled staff or KaVo trained technicians Use original KaVo spare parts only 2 2 2 Product specific WAR...

Page 10: ...l or grinder manufacturer CAUTION Damage by liquids Faults on electrical components Protect openings of the product from any ingress of liquids Do not continue using the device and contact Customer Se...

Page 11: ...for use and ensuring that all inspections and service tasks are performed This product has only been approved for use indoors The overarching guidelines and or national laws national regulations and...

Page 12: ...umber K ERGOgrip 4944 hand piece Mat no 1 003 7555 Grip sleeve Mat no 1 003 8708 Clamp Mat no 1 004 1148 Cleaning brush Mat no 0 229 3205 Instructions for use 3 4 Technical Data Speed Range 1 000 to 5...

Page 13: ...rmittent mode Operating time 2 minutes ON Pause time 8 minutes OFF Requirements classification Degree of soiling 2 Overvoltage category II Transportation and storage conditions Temperature range 20o C...

Page 14: ...Note Do not switch the handpiece on while the chuck is open Note When it is new you can hear a soft irregular clicking or buzzing at high speeds of the micromotor This bearing noise is completely nor...

Page 15: ...lip into the tip and unscrew the tip in the direction indicated by the arrow Pull the tip towards you Note Removing the tip may leave the felt disk loose in the tip or on the rotor If the felt disk is...

Page 16: ...nd turn the knob in the di rection indicated by the arrow until the chuck closes completely you will hear a double click Note Once you have inserted the tool insert the tool as far as it will go tool...

Page 17: ...Instructions for use K ERGOgrip 4944 5 Operation 5 3 Operation Operate the handpiece as specified in the instructions for use of the upstream control unit 17 30...

Page 18: ...all bearings Removing ball bearings Unscrew the knob from the handpiece and pull off the connection cable in the direction indicated by the arrow Take hold of the handpiece by the grip sleeve insert t...

Page 19: ...sleeve and pull the motor unit off the sleeve Take the ring off the motor unit DANGER Risks due to strong permanent magnet field The functions of implanted systems such as pacemakers can be influence...

Page 20: ...he rotor with a fork wrench 7 mm and screw the threaded ring tight using the socket wrench left hand thread Push the rotor into the stator Place the ring on the motor unit and push into place Use the...

Page 21: ...d tighten with the clip in the direction indi cated by the arrow Note Check the handpiece after exchanging the ball bearing Run through the speed range of the handpiece and check for unusual noise Not...

Page 22: ...oving the chuck Take hold of the handpiece by the grip sleeve insert the clip into the tip and unscrew the tip in the direction indicated by the arrow Pull the tip towards you Note Removing the tip ma...

Page 23: ...ck opens again completely The chuck is released Pull the chuck towards you Use the cleaning brush to clean the chuck and front opening on the hand piece Fitting the chuck Push the chuck into the openi...

Page 24: ...the chuck KaVo recom mends a grip test at 50 N Note Only use tools that work properly Follow the instructions of the tool manufacturer 6 2 2 Cleaning the grip sleeve Note Do not use oil containing cl...

Page 25: ...k the controls and have them repaired if necessary The tool is not tightly held by the chuck Tool shaft and chuck diam eters are not the same Use a tool chuck with a suitable diameter Chuck is worn Re...

Page 26: ...r use K ERGOgrip 4944 8 Accessories 6 2 Cleaning 26 30 8 Accessories Presentation Material summary Material number Handpiece tray 1 005 3460 Chuck 3 00 mm 1 003 8262 Socket wrench 1 004 0255 Docking g...

Page 27: ...Instructions for use K ERGOgrip 4944 9 Spares 6 2 Cleaning 9 Spares 05 2007 27 30...

Page 28: ...Instructions for use K ERGOgrip 4944 10 Declaration of conformity 6 2 Cleaning 28 30 10 Declaration of conformity...

Page 29: ......

Page 30: ...1 005 4230 Fk 20140422 3 en...

Reviews: