KaVo INTRAFLEX LUX 2 2307 LN Instructions For Use Manual Download Page 26

Instructions for use INTRAflex LUX 2 Programm 2307 LN - 0.535.6190, 2320 LN - 0.535.6180, 2325 LN -
0.535.6210

9 Terms and conditions of warranty

26 / 28

9 Terms and conditions of warranty

The following warranty conditions apply to this KaVo medical device:

KaVo provides the end customer with a warranty of proper function and guar-
antees zero defects in respect of material and workmanship for a period of 12
months from the date of the invoice, subject to the following conditions:
In case of justified complaints, KaVo will honour its warranty with a free re-
placement or repair. Other claims of any kind whatsoever, in particular with re-
spect to compensation, are excluded. In the event of default, gross negligence
or intent, this shall only apply in the absence of mandatory legal regulations to
the contrary.
KaVo shall not be liable for defects and their consequences that have arisen or
may arise from natural wear, improper handling, cleaning or maintenance, non-
compliance with operating, maintenance or connection instructions, calcination
or corrosion, contaminated air or water supplies or chemical or electrical factors
deemed abnormal or impermissible in accordance with KaVo's instructions for
use or other manufacturer's instructions. The warranty granted does not usually
extend to lamps, optical fibres made of glass and glass fibres, glassware, rub-
ber parts, and the colourfastness of plastic parts.
All liability is excluded if defects or their consequences originate from manipula-
tions or changes to the product made by the customer or a third party that is
not authorised by KaVo.
Warranty claims will only be accepted if the product is submitted along with
proof of purchase in the form of a copy of the invoice or note of delivery. The
dealer, purchase date, type, and serial number must be clearly evident from
this document.

Summary of Contents for INTRAFLEX LUX 2 2307 LN

Page 1: ...Instructions for use INTRAflex LUX 2 Programm 2307 LN 0 535 6190 2320 LN 0 535 6180 2325 LN 0 535 6210...

Page 2: ...stributed by KaVo Dental Technologies LLC 11727 Fruehauf Drive Charlotte NC 28273 USA Phone 847 550 6800 Fax 847 550 6825 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo c...

Page 3: ...LN or 2320 LN 16 5 4 Removing INTRA LUX head from shanks 2307 LN or 2320 LN 17 5 5 Insert the milling cutters or diamond grinders in contra angle 2325 L 17 5 6 Removing the cutting tools or diamond gr...

Page 4: ...8 Tools and consumables 25 9 Terms and conditions of warranty 26 Instructions for use INTRAflex LUX 2 Programm 2307 LN 0 535 6190 2320 LN 0 535 6180 2325 LN 0 535 6210 Table of contents 4 28...

Page 5: ...duling or if you have any questions please contact KaVo Repair Service KaVo Dental Technologies LLC 11727 Fruehauf Drive Charlotte NC 28273 USA Toll free Direct Customer Service 1 888 ASK KAVO 888 275...

Page 6: ...nditions Temperature range Transportation and storage conditions Air pressure Transportation and storage conditions Humidity Protect from moisture Protect from impact HIBC Code Hazard levels The warni...

Page 7: ...Instructions for use INTRAflex LUX 2 Programm 2307 LN 0 535 6190 2320 LN 0 535 6180 2325 LN 0 535 6210 1 User instructions NOTICE In cases which if not prevented could lead to material damage 7 28...

Page 8: ...product and accessories appropriately before disposal If there is any injury to soft tissue do not continue treatment in the oral cavity with compressed air driven instruments 2 2 Technical condition...

Page 9: ...ouch soft tissue with the handpiece head or instrument cover Do not use the medical device as a light probe Use an appropriate light probe for illumination of the oral cavity or site of preparation Af...

Page 10: ...tions for use This medical device is intended for dental treatment only All other types of use or modifications of the product are not permitted and can be hazardous The medical device is intended for...

Page 11: ...lf the patient and third parties from hazards to prevent contamination from the product 3 2 Technical Specifications 3 2 1 Reducing shank 2307 LN Identification 1 green ring Transmission ratio 2 7 1 D...

Page 12: ...o 3 0 bar 29 to 44 psi Air consumption 50 to 60 Nl min Speed range 60 000 to 140 000 min 1 Idle torque at 3 0 bar 44 psi 0 32 Ncm Handpiece cutters or grinders can be used Attachable to all MULTIflex...

Page 13: ...r Contaminated and moist cooling air can cause malfunctions Make sure that the supply of cooling air is dry clean and uncontaminated according to ISO 7494 2 4 1 Mount the MULTIflex LUX MULTIflex LED c...

Page 14: ...Instructions for use INTRAflex LUX 2 Programm 2307 LN 0 535 6190 2320 LN 0 535 6180 2325 LN 0 535 6210 4 Start up and shut down 4 2 Checking the amount of water 14 28...

Page 15: ...731 between the coupling and the medical device and check the following pressures Drive pressure drive pressure recommended return air pressure spray water pressure and spray air pressure Drive pressu...

Page 16: ...ED of the coupling or reduce its service life Make sure that the turbine is accurately coupled and firmly seated on the coupling Mount the medical device accurately on the MULTIflex LUX MULTIflex LED...

Page 17: ...rs with worn or damaged shafts Risk of injury tool may fall out during treatment Never use dental burs or diamond grinders with damaged or worn shafts CAUTION Danger of injury from cutters or grinders...

Page 18: ...e 2325 LN WARNING Hazard from rotating dental bur or diamond grinder Lacerations and damage to the chuck system Do not touch the dental bur or diamond grinder when it is rotating Do not press the push...

Page 19: ...be lubricated with a cotton ball wetted with KaVo Spray Press the O ring between your fingers to form a loop Push the O ring to the front and remove it Insert new O rings into the grooves 6 2 Cleanin...

Page 20: ...tool Reprocess the medical device as soon as possible after treatment To minimise the risk of infection during reprocessing always wear protect ive gloves Remove the tool from the medical device Remov...

Page 21: ...ds the following products based on compatibility of the materi als The microbiological efficacy must be ensured by the disinfectant manufac turer and proven by an expert opinion Approved disinfectants...

Page 22: ...KaVo CLEANpac bag and place it on the corresponding care adapter Press the spray key for 1 to 2 seconds Care of clamping chuck Note Only possible for the INTRAflex contra angle KaVo recommends servici...

Page 23: ...ether with the guide bush of the chuck to be ser viced against the tip of the service coupling Press the button marked with the chuck service symbol Note Close the chuck service mode Option 1 Place th...

Page 24: ...lowing sterilisation processes Steriliser with triple pre vacuum at least 3 minutes at 135 C 275 F Drying time 16 min Steriliser using the gravity method at least 10 minutes at 135 C 275 F Drying tim...

Page 25: ...shanks 2307 LN 2320 LN INTRAflex LUX contra angle handpiece 2325 LN Instrument stand 3 005 5204 X X Insert for IN TRAflex 3 005 3089 X X Cellulose pad 100 units 0 411 9862 X X Cleanpac 10 units 0 411...

Page 26: ...ot be liable for defects and their consequences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connection instru...

Page 27: ......

Page 28: ...1 013 8706 Fk 20190214 01 en...

Reviews: