Instructions for use PROPHYflex 3 - 2018 - 1.000.4672, - 1.006.9926, - 1.006.9928
9 Terms and conditions of warranty | 7.8 Storage

24 / 26

9 Terms and conditions of warranty

The following warranty conditions apply to this KaVo medical device:
KaVo provides the end customer with a warranty of proper function and guarantees
zero defects in respect of material and processing for a period of 12 months from the
date of the invoice, subject to the following conditions:
In case of justified complaints, KaVo will honour its warranty with a free replacement
or repair. Other claims of any nature whatsoever, in particular with respect to compen‐
sation, are excluded. In the event of default, gross negligence or intent, this shall only
apply in the absence of mandatory legal regulations to the contrary.
KaVo shall not be liable for defects and their consequences that have arisen or may
arise from natural wear, improper handling, cleaning or maintenance, non-compliance
with operating, maintenance or connection instructions, calcination or corrosion, con‐
taminated air or water supplies or chemical or electrical factors deemed abnormal or
impermissible in accordance with KaVo's instructions for use or other manufacturer's
instructions. The warranty granted does not usually extend to lamps, light conductors
made of glass and glass fibres, glassware, rubber parts, and the colourfastness of
plastic parts.
All liability is excluded if defects or their consequences originate from manipulations or
changes to the product made by the customer or a third party that is not authorised by
KaVo.
Warranty claims will only be accepted if the product is submitted along with proof of
purchase in the form of a copy of the invoice or note of delivery. The dealer, purchase
date, type, and serial number must be clearly evident from this document.

 

Summary of Contents for 1.000.4672

Page 1: ...Instructions for use PROPHYflex 3 2018 1 000 4672 1 006 9926 1 006 9928 Always be on the safe side ...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com ...

Page 3: ...PHYflex Pulver PROPHYpearls PROPHY Superpearls PROPHYflex Perio Powder 13 6 Troubleshooting 18 6 1 Cleaning a blocked cannula 18 6 2 Cleaning the main body 18 7 Preparation methods according to ISO 17664 19 7 1 Preparation at the site of use 19 7 2 Cleaning 19 7 2 1 Manual cleaning of the exterior 19 7 2 2 Automated external cleaning 19 7 2 3 Manual cleaning of the inside 19 7 2 4 Automated intern...

Page 4: ...y KaVo Dental GmbH Refer to the chapter on Safety Warning symbol Important information for users and service technicians Can be steam sterilised at 134 o C 1 o C 4 o C 273 o F 1 6 o F 7 4 o F Thermodisinfectable CE Zeichen Communauté Européenne Ein Produkt mit diesem Zeichen entspricht den Anforderungen der anwendbaren EG Richtlinie Action request Target group This document is intended for dentist...

Page 5: ...perty damage and injury CAUTION CAUTION indicates a hazardous situation that can cause damage to property or mild to moder ate injuries WARNING WARNING indicates a hazardous situation that can lead to serious or fatal injury DANGER DANGER indicates a maximal hazard due to a situation that can directly cause death or fatal injury 2 2 Safety instructions WARNING Hazard to the care provider and patie...

Page 6: ... a salt free or low salt diet patients with renal insufficiency chronic diseases of the respiratory sys tem and chronic diarrhoea In such cases check if an alternative treatment with PROPHYpearls or PRO PHY Superpearls is possible CAUTION Safety checks since cleansers and disinfectants can attack the plastic housing This can cause hairline cracks and other damage to arise which can lead to a hazar...

Page 7: ...dentist does not unnecessarily inhale the powder Note The patient should rinse his or her mouth with water after treatment Note After successful treatment with the PROPHYflex all tooth surfaces should be pol ished Note PROPHYpearls have a low degree of water solubility and can therefore collect in the amalgam separator which will then have to be changed more frequently Clean the suction hoses of t...

Page 8: ... dentistry Please refer also to the Instructions for Use A medical device according to relevant national statutory regulations Proper use According to these regulations this medical device may only be used for the descri bed application by a knowledgeable user You need to comply with the following the applicable health and safety regulations the applicable accident prevention regulations these Ins...

Page 9: ...pearls 1 P nozzle G 1 x P nozzle K recess 3 4 Transportation and storage conditions CAUTION It is hazardous to start up the medical device after it has been stored strongly refriger ated This can cause the medical device to malfunction Prior to start up very cold products must be heated to a temperature of 20o C to 25o C 68o F to 77o F Temperature 20 C to 70 C 4 F to 158 F Relative humidity 5 RH t...

Page 10: ...ex LUX MULTIflex LED coupling onto the turbine hose and tighten with the wrench The water fraction of the spray can be controlled through rotating the spray ring on the MULTIflex LUX MULTIflex LED coupling The water volume has a crucial effect on the cleaning efficiency and on dust develop ment Small water volume little cleaning efficiency and a lot of dust Large water volume great cleaning effici...

Page 11: ... 1 006 9926 1 006 9928 4 Start up and shut down 4 4 Check O rings 4 4 Check O rings CAUTION Missing or damaged O rings Malfunctions and premature failure Make sure that all O rings are on the coupling and undamaged Number of available O rings 5 11 26 ...

Page 12: ...is secure by pulling on it 5 2 Remove the medical device Hold the coupling tight and pull the medical device off while twisting slightly 5 3 Filling the powder container Unscrew the powder container to the left against the direction of the arrow Before filling the powder container shake the powder in the refilling bag well Screw on the powder container straight on to the right in the direction of ...

Page 13: ...TION The marks must be adjacent otherwise the cannula can come loose If the cannula comes off during treatment it could substantially endanger the patient and user Pull on the cannula each time before treatment and check its seat Before each treatment make sure that the cannula operates properly 5 5 Removing the cannulas Turn the cannula all the way to the left in the direction of the arrow and re...

Page 14: ...ROPHYflex powder CAUTION Hazard from the use of PROPHYflex on the gingiva The gingiva may be damaged Do not direct the powder jet toward the gingiva Always work from pink to white The front part of the instrument can be rotated to reach the optimum working position at all times The powder spray can be guided from the occlusal margin to the cervical margin of the tooth without danger of injuring th...

Page 15: ...ired local amount as the red is re moved The jet should not directly contact the gingival margin exposed tooth necks or the mucosa The handpiece tip should be held approximately 3 5 mm from the sur face of the tooth It is important to position the cannula at an angle of 10o to 60o in relation to the treated tooth surface to generate a rolling effect and thereby optimise the absorption of the spher...

Page 16: ...ater mixture is pro duced Getting the patient ready Apply some Vaseline ointment to the patient s lips This prevents the lips from becoming dry and cracking Hook the small saliva ejector into the corner of the patient s mouth such that it as pirates underneath the tongue Use the large suction cannula for aspiration of the water powder mixture bouncing off the tooth Treating the patient Note Please...

Page 17: ...8 5 Operation 5 6 Instructions for use for PROPHYflex Pulver PROPHYpearls PROPHY Superpearls PROPHYflex Per io Powder 30 60 Glycine PROPHYflex Perio Powder working angle 30o to 60o During the treatment keep the suction cannula close to the tooth treated with the jet 17 26 ...

Page 18: ...leaned with a cloth once per week 6 1 Cleaning a blocked cannula Remove the cannulas Twist the nozzle needle from the front and then from the back into the cannula The remove the nozzle needle and blow out the cannula with compressed air 6 2 Cleaning the main body To prevent blockages we recommend cleaning the main body once every week and prior to each thermal disinfection or sterilization Remove...

Page 19: ...solution or similar 7 2 Cleaning CAUTION Malfunctions from cleaning in the ultrasonic unit Defects in the product Only clean manually or in a thermodisinfector 7 2 1 Manual cleaning of the exterior Required accessories Tap water 30o C 5o C 86o F 10o F Brush such as a medium hard toothbrush Brush off under flowing tap water 7 2 2 Automated external cleaning KaVo recommends thermodisinfectors in acc...

Page 20: ...ing agents with a pH value of max 10 e g Miele G 7781 G 7881 Validation was carried out with Programme VARIO TD cleaning agent neodisher mediclean neutralisation agent neodisher Z and rinsing agent neodisher mielclear and only applies to the material compatibility with KaVo prod ucts For program settings as well as cleansers and disinfectants to be used please re fer to the Instructions for Use of...

Page 21: ...lies to the material compatibility with KaVo prod ucts For program settings as well as cleansers and disinfectants to be used please re fer to the Instructions for Use of the thermodisinfector complying with max pH value of 10 7 4 Drying Manual Drying Blow off the outside and inside with compressed air until water drops are no lon ger visible Automatic Drying The drying procedure is normally part ...

Page 22: ...nticlockwise and drain and clean it before each thermal disinfection or sterilisation Do not screw the powder container back on be fore thermal disinfection or sterilisation Likewise clean off any powder residue from the PROPHYflex especially the cannulas tubes and P nozzle The KaVo medical device has a maximum temperature resistance of up to 138 280 4 F Select a suitable procedure depending on th...

Page 23: ... Powder berry Pack of 80 sticks Mat no 1 007 0015 PROPHYflex Powder cherry Pack of 80 sticks Mat no 1 007 0016 PROPHYflex Powder mint Pack of 80 sticks Mat no 1 007 0017 PROPHYpearls neutral Pack of 80 sticks Mat no 1 010 1826 PROPHYpearls mint Pack of 80 sticks Mat no 1 010 1828 PROPHYpearls peach Pack of 80 sticks Mat no 1 010 1829 PROPHYpearls orange Pack of 80 sticks Mat no 1 010 1830 PROPHYpe...

Page 24: ...ble for defects and their consequences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connection instructions calcination or corrosion con taminated air or water supplies or chemical or electrical factors deemed abnormal or impermissible in accordance with KaVo s instructions for use or other manufacturer s ins...

Page 25: ......

Page 26: ...1 000 6601 kb 20140210 07 en ...

Reviews: