background image

Instructions for use

MULTIflex LUX coupling Midwest - 0.553.1390

Summary of Contents for 0.553.1390

Page 1: ...Instructions for use MULTIflex LUX coupling Midwest 0 553 1390...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 0 7351 56 0 Fax 49 0 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Page 3: ...shooting 13 6 1 Checking for malfunctions before initial start up 13 6 2 Troubleshooting 13 6 2 1 Exchanging the O rings 13 7 Reprocessing steps in accordance with ISO 17664 14 7 1 Preparations at the...

Page 4: ...KaVo Technical Service If you have any questions or complaints please contact the KaVo Technical Service 49 0 7351 56 1000 service instrumente kavokerr com Target group This document is intended for...

Page 5: ...dity Protect from moisture Protect from impact HIBC Code Hazard levels The warning and safety notes in this document must be observed to prevent personal injury and material damage The warning notes a...

Page 6: ...osal 2 2 Technical condition A damaged device or components could injure patients users and third parties Only operate devices or components if they are undamaged on the outside Check that the device...

Page 7: ...re authorised to do this Service technicians of KaVo branches after the appropriate product training Service technicians of KaVo authorised dealers after the appropriate product training Observe all t...

Page 8: ...d by expert users and for the specified application exclusively You need to comply with the following the applicable health and safety regulations the applicable accident prevention regulations these...

Page 9: ...conditions NOTICE Startup after refrigerated storage Malfunction Prior to startup strongly refrigerated products must be allowed to warm up to a temperature of 20 C to 25 C 68 F to 77 F Temperature 2...

Page 10: ...so 2 7 Reprocessing steps in accordance with ISO 17664 Page 14 WARNING Dispose of the product in appropriate manner Infection hazard Reprocess and sterilise the product and accessories before disposal...

Page 11: ...e 5 2 Removing the coupling from the hose In order to remove the coupling rotate the sleeve of the hose in anticlock wise direction and take the coupling off the hose 5 3 Attaching instruments WARNING...

Page 12: ...uctions for use MULTIflex LUX coupling Midwest 0 553 1390 5 Operation 5 4 Removing instruments 12 20 5 4 Removing instruments Hold the coupling tight and pull the instrument forward while twisting sli...

Page 13: ...staff NOTICE Missing or damaged O rings Malfunction and premature failure Make sure that all O rings are on the coupling and are undamaged Note Stop working if the O ring is missing or damaged 6 2 Tro...

Page 14: ...reprocessing always wear protect ive gloves Remove the tool from the medical device Remove all residual cement composite or blood immediately Do not place in solutions or similar substances 7 2 Manua...

Page 15: ...e product and let it work ac cording to the disinfectant manufacturer Follow the instructions for use of the disinfectant 7 2 4 Manual disinfection internal Not applicable 7 2 5 Manual drying Blow off...

Page 16: ...0 553 1390 7 Reprocessing steps in accordance with ISO 17664 7 4 Sterilisation 16 20 7 4 Sterilisation Non sterilisable 7 5 Storage Reprocessed products should be stored protected from dust with mini...

Page 17: ...or use MULTIflex LUX coupling Midwest 0 553 1390 8 Tools 8 Tools Available from dental suppliers Material summary Mat No Key 0 411 1563 Spare washer 0 553 4762 O ring large 1 004 2776 O ring small 1 0...

Page 18: ...nd their consequences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connection instructions calcination or corr...

Page 19: ......

Page 20: ...0 589 2002 bd 20190809 08 en...

Reviews: