background image

 

 

 

3 / 14 

 

 

 

 

 
 

 
Foreword 

 

Dear customer, 
 
Thank you for choosing a high-quality Kauko Xi-M computer! Our computers are developed and 
manufactured in accordance with precise quality guidelines. You have purchased a high-quality 
product with strict quality control and a long life expectancy. All units are carefully burn-in tested at 
factory before delivery.   
 
We have developed and manufactured your Kauko computer with the best possible components, 
offering many years of uninterrupted, carefree operation. 
 
To ensure long-term stability, a very efficient passive direct copper cooling system has been 
developed for the Kauko Xi-M models. Thanks to the closed aluminum housing, no dust or dirt can 
get into the housing, which means it is no longer necessary to open the housing for maintenance. 
The computer’s simple and stylish design makes it hygienic and easy to clean. Its low 
maintenance, long life cycle and high performance allow you to concentrate on your day-to-day 
operations. 
 
We wish you a lot of enjoyment with your Kauko computer, and thank you again for choosing us as 
your partner! 
 
 
Your Kauko team 
 
 
 
 
 

 

 

 

NOTE! 

To avoid the risk of electric shock, this unit must only be connected to a 
mains power supply with a ground connector! 

 

Summary of Contents for XI-M

Page 1: ...1 14 KAUKO XI M COMPUTER User manual ...

Page 2: ...densation 5 Choice of location 6 2 Patient environment 6 Electrical safety according to IEC EN 60601 1 6 Safety instructions for operation in the patient environment 7 3 Integration in a medical system 7 4 Operation in a network 7 5 Safe operation 7 Data protection 7 Protection from power outages 8 Care and maintenance 8 Cleaning the housing 8 6 Liability and warranty 9 Contact and service 9 Discl...

Page 3: ...term stability a very efficient passive direct copper cooling system has been developed for the Kauko Xi M models Thanks to the closed aluminum housing no dust or dirt can get into the housing which means it is no longer necessary to open the housing for maintenance The computer s simple and stylish design makes it hygienic and easy to clean Its low maintenance long life cycle and high performance...

Page 4: ...4 14 ...

Page 5: ... validated by Kauko may be used If any visible damage corrosion heat sparks or smoke is detected in the mains power line the cable should be replaced immediately with a new one that has been validated by Kauko With the transfer or resale of the unit the same procedure must be followed If these instructions are not complied with the unit loses its conformity and there is a potential danger to the l...

Page 6: ...on from Kauko s support personnel and only components that have been tested and validated by Kauko may be used An unauthorized change to the unit s configuration will result in an immediate loss of conformity and can endanger the health of the user and or the patients and other people as electrical safety can no longer be guaranteed Ingress of foreign objects and liquids With any unintended intrus...

Page 7: ...has a unique VESA mounting solution integrated on the housing 2 Patient environment To protect your patients from electrical influences prevent contact between the patients and the computer housing The Kauko Xi M is a computer that was developed and tested for use in the vicinity of patients It fulfills the requirements of the EN IEC 60950 and EN IEC 60601 1 2 standards and the power supply fulfil...

Page 8: ... a medical electrical system the requirements of the valid version of IEC 60601 1 and possibly the requirements of the medical product guidelines 93 42 EEC 2007 47 EC are to be complied with and the risk evaluation must be done by the system creator The Kauko Xi M computer must only be electrically connected and operated with products and devices that comply with the requirements of the standards ...

Page 9: ... In addition to these unit related maintenance recommendations the legal requirements of national accident prevention regulations for electrical installations and equipment must be complied with Cleaning the housing You can clean the housing and power supply of your Kauko Xi M computer with a clean lint free and anti static cloth Always ensure that the computer is switched off and the mains supply...

Page 10: ...proper handling incorrect operation faulty connection non compliance with legal requirements and or external influences There is no entitlement to an indemnity or compensation for loss of use No liability for the functionality of the software can be assumed The person and or company responsible must ensure that the software used has been verified and validated We are not liable for any possible ad...

Page 11: ... supply connector 2 RJ45 Ethernet connector 3 Mini Display Port connectors 4 USB 3 connectors 5 WiFi antenna connector 6 Ground connector 7 Serial port 8 USB 2 connectors 9 Front panel USB 3 connectors 10 Front panel audio connector 3 5mm 11 Power button ...

Page 12: ...12 14 Dimensional drawing Identification Marking plate can be found on the bottom plate of the computer ...

Page 13: ...Intel AC WLAN optional Housing Anodized aluminum unibody VESA100 mount through Power supply External 12V medical PSU Graphic Integrated graphics support for processors with Intel Graphics Technology Sound system Intel High Definition Intel HD Audio via the Mini Display Port 1 2 interfaces through the processor Realtek HD Audio via a stereo microphone headphone 3 5 mm jack on the front panel LAN Gi...

Page 14: ...Kauko Oy Itämerenkatu 5 00180 Helsinki PL 116 00520 Helsinki P 358 9 5211 Fax 358 9 521 6641 info kauko com www kauko com ...

Reviews: