14
www.katusensor.com
Only remove the switch in case of power failure (electrical, hydraulic/pneumatic).
Switch disconnection from pressure and power supply must be performed by trained
or directed personnel in accordance with the most advanced standards.
!
danger
Maintenance/cleaning
Disassemble
The pressure switch does not require maintenance.
Periodically check whether the switch is working properly.
If the switch does not work properly, stop the operation immediately.
!
warning
Be aware that the surface of the shell may become very hot if the operating
temperature is higher!
!
warning
Use of improper cleaning agent may damage the switch.
The following cleaning agents can be used to clean polycarbonate: mild soap or detergent
Isopropyl alcohol
Immediately after cleaning, rinse with water. Do not leave cleaner on the surface of the
product. Do not clean products in high heat or direct sunlight.
The following cleaning agents are known to affect the integrity of polycarbonate
components and should not be used: ZEP Fast 505, Pinesol, Formula 409
Halogenated solvents (benzene, gasoline, acetone or carbon tetrachloride)
Strong alkalinity
Methyl ethyl ketone
Abrasive substance
!
caution
H0
Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed:
At the press of a button, the value increases; Hold the button down and the value will keep changing.
dap
Switch point damping/process data flow (IO-Link communication) and display.
(Factory default: 0.06)
Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed:
At the press of a button, the value increases; Hold the button down and the value will keep changing.
dis
Update rate and direction of the display (d1 by default)
Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed:
At the press of a button, the value increases; If you hold the button down, the value will keep changing.
[d1] : The measured value is updated every 10ms
[d2] : The measurement is updated every 100ms
[d3] : Update measurement every 600ms
zeao
Zero excision value (full scale %) (factory default is 0.5)
Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed:
At the press of a button, the value increases; Hold the button down and the value will keep changing.
daa
Display refresh time: analog 0.1s (factory default is 0.01)
Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed:
At the press of a button, the value increases; Hold the button down and the value will keep changing.
iout
Output analog switch:
Current type: 4-20: (4-20mA)
20-4: (20-4mA)
0-20: (0-20mA)
20-0: (20-0mA)
5V voltage type: 1-5: (1-5V)
5-1: (5-1V)
0-5: (0-5V)
5-0: (5-0V)
10V voltage type: 1-10: (1-10V)
10-1: (10-1V)
0-10: (0-10V)
10-0: (10-0V)
Hold down [+] or [-] for at least 1s. After 1 second: The setting value can be changed:
At the press of a button, the value increases; Hold the button down and the value will keep changing.
EF
Expand functionality/Open the Level 2 menu
Press the [M] key to enter the Extended 2 level menu
Press [+] to exit.