KATU 500 Series Operation Instructions Manual Download Page 1

500 series 

operation instructions

Sensor and controller

Flow      pressure      temperature      level      position

Summary of Contents for 500 Series

Page 1: ...500 series operation instructions Sensor and controller Flow pressure temperature level position...

Page 2: ...onditions Security of loss Such as Incorrect use Incorrect installation Incorrect operation or operation in violation of the provisions of this operation manual No liability shall be assumed for any d...

Page 3: ...sult in fatal injury danger An identifiable hazard Failure to comply may result in fatal injury and damage to equipment or plant parts warning It means a danger Non compliance may result in minor inju...

Page 4: ...modes Switching function If the switch is higher or lower than the set switching limit SP rP its switching state is changed The following switch functions can be selected Hysteresis function normally...

Page 5: ...e intended to protect users from dangerous situations and or prevent material damage In the operating instructions the severity of the potential risk can be indicated by the following signal words Ins...

Page 6: ...output SP1 IO Link Analog output voltage or current Level 2 menu res factory data reset Hold down to restore factory Settings ou1 Switch 1 signal Factory default is HNO Hysteresis function HNO normall...

Page 7: ...changed At the press of a button the value increases Hold the button down and the value will keep changing ds2 OUT2 s opening delay The factory default is 0s Hold down or for at least 1s After 1 secon...

Page 8: ...connecting cable is damaged Do not use any sharp hard objects to make entries The key may be damaged by something sharp and hard caution Two way switch one analog 12 30VDC PNP Analog quantity 1 2 4 5...

Page 9: ...he button down and the value will keep changing rp2 Switch 2 Reset value Factory default value is SP2 0 5 Hold down or for at least 1s After 1 second The setting value can be changed At the press of a...

Page 10: ...y The factory default is 0s Hold or for at least 1s After 1 second The setting value can be changed At the press of a button the value increases Hold the button down and the value will keep changing d...

Page 11: ...on the value increases Hold the button down and the value will keep changing H0 The maximum value of system measurement history Hold down or for at least 1s After 1 second The setting value can be cha...

Page 12: ...ill keep changing daa Display refresh time analog 0 1s factory default is 0 01 Hold down or for at least 1s After 1 second The setting value can be changed At the press of a button the value increases...

Page 13: ...12 www katusensor com Display menu Display menu Level 1 menu Level 2 menu The one circuit switch does not have this function...

Page 14: ...13 www katusensor com Display menu Level 2 menu No analog model does not have this function...

Page 15: ...g process data flow IO Link communication and display Factory default 0 06 Hold down or for at least 1s After 1 second The setting value can be changed At the press of a button the value increases Hol...

Page 16: ...Katu Electronic Kunshan Co Ltd The phone number is 400 150 8815 Website www katusensor com Factory No 1120 Jinyang East Road Kunshan City Suzhou City...