7 / 16
Selecting the installation site
When choosing the installation place, bear in mind that the rear of the CAP converter should always be
accessible. The CAP converter is equipped with a power saving circuit, which means that the unit does not
need to be placed where it is visible. This allows you to install the CAP converter out of sight in any position,
e.g. on cabinet walls, side panels or storage shelves.
The four screw holes make it possible to place the CAP converter on a fi rm horizontal surface but also to
screw it on in any desired position.
When choosing the installation place, observe the following:
●
The wall thickness of the installation surface must be at least 15 mm, otherwise the screws will come out the back or
damage the surface.
●
The cabinet or storage compartment in which the device is to be installed must be suffi ciently ventilated to prevent
heat accumulation. Carpet-covered walls are unsuitable for installation.
●
When screwing in the screws, do not damage any cables or similar that are routed behind or in the installation wall.
●
The CAP converter is exclusively intended for installation in dry indoor areas.
●
The cable lengths must be taken into account when choosing the installation place.
●
Strain-relieve the connecting cables.
Connections and fuses
All connecting cables are connected to the rear of the CAP converter. Viewed from the front, there is a fuse inserted
from the outside on the left side of the CAP converter. This fuse must also be accessible after installation of the CAP
converter so that it can be easily replaced if necessary. For more information about the type of fuse, see the sticker on
the CAP converter and the fuse itself.
Ventilation
The heat generated in the CAP converter is dissipated on
all sides of the housing. When selecting the installation
place, make sure that these sides are not obstructed or
covered. If the device is permanently insuffi ciently venti-
lated, this may have a negative eff ect on the service life of
the device!
Maintain a clearance of at least 20 cm above/below, 2 cm
to each side and 5 cm behind and in front of the device to
allow unobstructed heat dissipation.
Material damage to the device during operation due to insuffi cient ventilation!
The operating temperature is measured by the device. Continuous operation at temperatures higher than
the recommended operating temperature may cause premature failure of the device as a result of insuffi -
cient ventilation. This is not a warranty or guarantee case!
The CAP converter may only be operated at the recommended operating temperature.
2 cm
20 cm
5 cm
2 cm
5 cm
Minimum
clear
ance