is not restored to desired level, replace cartridge with new Ultra Flow Filter
Cartridge.
Clogged Outlet valve: Unscrew cap counterclockwise from the bag. Then
screw the filter counterclockwise out of the cap. Swish cap in water to remove
any sediment from connection.
Add the output hose and flush the cap and the hose with clean water. If clean
water is unavailable, flush the system with the first liter of treated water when
you start filtering water again.
2. If System Leaks Near the Cap
Defective or missing seal: Unscrew cap counterclockwise from the bag. Check
if the white seal is still in place and not damaged. If not replace it (Figure 5).
LONG TERM STORAGE (AFTER YOUR TRIP IS OVER)
Disinfect your microfilter before storage to prevent microbiological growth
within the cartridge.
1.
Fill a 2 liter container with tap water and add 4 Micropur MP1 Purification
Tablets or Micropur Forte MF 1T. (If not available use 4 drops of ordinary
household bleach.)
2. Pour solution into water bag.
3. Hang bag and allow the entire amount of solution to run through cartridge
(into sink or container) to disinfect filter, hoses, bag, etc.
4. Unscrew the filter cartridge and cap. Remove the filter protector and flush all
parts with clean water.
5.
Allow the components to air dry completely before reassembling the filter.
6.
Store all dry components inside the carry bag.
Note: When removing unit from long-term storage, flush the system with 2 liters of
water to remove any stale tasting water.
(Figure 5)
White Seal