background image

2. Attach white quick connect insert (B) to the "short" section  of hose. Attach white quick con-

nect body (A) to the "long" section of the cut hose. Connect them together. (Figure 3-1)

3. If a direct connect to hydration bladder is desired, install the second white connector (C) to

the end of the output hose. This will match with many popular hydration systems. 
(Figure 3-2)

Option #2:

This configuration is ideal for pumping filtered water directly into hydration packs (such as
Camelbak). It allows quick filling without removing pack or bladder.
Note: Ensure quick connect fittings are correct size for your hydration pack drink hose (1/4"
inside diameter) before proceeding to Step 1.

1. Cut hydration pack drink hose at desired length (approximately 4 inches from end of drink

hose). See Figure 4-1

2. Connect white body (A) to long section of drink hose that attaches to hydration bladder.
3. Connect white insert (B) to short section of drink hose that attaches to bite valve. 
4. Connect the second white insert (C) to end of water filter output hose.
5. To fill bladder, connect white insert (C) on output hose to white body (A) on drink hose. Fill.

Reconnect bite valve. See Figure 4-2

Figure 3-1

Figure 3-2

EN 

Figure 4-1

Figure 4-2

(A)

(B)

(C)

(A)

(C)

(A)

(B)

(C)

8018522-0 Hiker-Hiker PRO Manual EU-11-Sprachen_CONTENT_103656-Katadyn-B-da1a

Summary of Contents for 8018280 Hiker Pro

Page 1: ...Hiker Pro Water Microfilter Model 8018280 Hiker Pro Replacement Cartridge Model 8014644 EN DE FR NL DK SWE NOR FIN IT ESP POR...

Page 2: ...lla terrigena and protozoan cysts 99 9 Giardia and Cryptosporidium Its com pact and lightweight design is easy to use and essential equipment for camping back packing and trekking Housing English Cart...

Page 3: ...ws easy filling of hydration bladders See illustration Figure 2 2 for installation PRODUCT SET UP The Hiker Pro requires minimal set up For best results try out the Hiker Pro before first field use to...

Page 4: ...tain your Katadyn water system to keep it operating smoothly 1 If handle is hard to push Lubricate pump handle o ring Silicone lubricant is provided with your new unit Remove handle collar and handle...

Page 5: ...bacteria Klebsiella terrigena and pro tozoan cysts Giardia and Cryptosporidium For maximum performance cartridge should be replaced after 750 liters or when the unit becomes hard to pump CARTRIDGE IN...

Page 6: ...und cartridge there will be approximately a 2 overlap and hold in place Slip the flexible netting over the cartridge Adjust filter protector screen and netting so they are posi tioned evenly The use o...

Page 7: ...oving pack or bladder Note Ensure quick connect fittings are correct size for your hydration pack drink hose 1 4 inside diameter before proceeding to Step 1 1 Cut hydration pack drink hose at desired...

Page 8: ...r suggestions please contact us at 41 44 839 21 11 PRODUCT REGISTRATION Please take a moment to register your new Katadyn product by completing the short product registration form online at www katady...