Cod. 2050-0001  Rev 1.1 

  

WARNING 

 

* The percentage of dissolved salts and other rejected elements is influenced by the quality 
of the water, the temperature, the pressure and the totality of dissolved salts and it is 
different depending on the types of salts or elements. 

** In the case of near-limit water use, contact your dealer for the tests. 

 

2.3

 

TECHNICAL SPECIFICATIONS 

 

 

EASY:FAST 

TECHNICAL SPECIFICATIONS

 

Height x Width x Depth (mm) 

168x515x476 

Weight (kg) 

20 

Approved Decibel Level under normal operating 
conditions (db) 

<70 

Membranes (nr. 4) 

TWB2A1 

Carbon Block filter 

Profine® BLUE small 

WATER SUPPLY SPECIFICATIONS

 

Water quality 

Drinkable 

Minimum water temperature (°C) 

Maximum water temperature (°C)** 

35 

Minimum inlet capacity (l/h) 

400 

Maximum inlet pressure 

500 kpa 

Minimum inlet pressure 

150 kpa 

LOCATION SPECIFICATIONS 

Maximum relative humidity (%) 

90 

Minimum location temperature (°C) 

Maximum location temperature (°C) 

40 

POWER SUPPLY SPECIFICATIONS 

Power supply type 

MON GROUND 

Nominal power (V) 

230 

Frequency (Hz) 

50/60 

Absorbed current (A) 

1.8A 

Power (W) 

180W 

Fuse type (electronic board) 

T3.15A 

PERMEAT CHARACTERISTICS 

Maximum capacity at 10° C (l/h) 

c.a 140 

Flow rate with back pressure of 0.3 MPa at 15 ° C (l/h) 

c.a 110 

Recovery percentage (%)* 

25-30% with hard water 

40% with medium-hard water 

55-60% with soft water 

AUTONOMY AND REPLACEMENT CONDITIONS 

Profine® BLUE small 

Max.100 h 

Inverse osmosis membranes 

Max 3 year 

Vane pump and solenoid valve 

2000 ore with treated water 

 

Summary of Contents for EASY:FAST

Page 1: ...1 Cod 2050 0001 Rev 1 1 EASY FAST MANUAL EQUIPMENT FOR POTABLE WATER TREATMENT...

Page 2: ...DIRECT SUN ACTION AND FROM THE FROST MAKE SURE THAT ACCESS TO THE APPLIANCE IS ALLOWED ONLY TO QUALIFIED PERSONAL BEFORE USING THE USER HAS TO READ THIS MANUAL CAREFULLY AND TAKE NOTE OF THE WARNINGS...

Page 3: ...INSTALLATION 9 3 2 EXCHANGE OF THE CAPILLARY 10 4 FUNCTIONING 11 4 1 FIRST START UP 11 4 2 NORMAL USE 11 4 3 MIX 11 4 4 LOW PRESSURE ALARM 11 4 5 LEAKAGE ALARM 11 4 6 INACTIVITY 11 4 7 ELECTRONIC BOA...

Page 4: ...nly perform the operations described in this manual and they have not to perform tasks reserved to maintenance or qualified technician WARNING This equipment needs regular maintenance in order to guar...

Page 5: ...pment in the absence of periodic maintenance IT IS STRICTLY FORBIDDEN to use the equipment in hygienic conditions or environments that aren t in compliance with those indicated in this manual IT IS ST...

Page 6: ...able Minimum water temperature C 5 Maximum water temperature C 35 Minimum inlet capacity l h 400 Maximum inlet pressure 500 kpa Minimum inlet pressure 150 kpa LOCATION SPECIFICATIONS Maximum relative...

Page 7: ...NNER LAYOUT 1 By pass valve and mix 2 Inlet solenoid valve 3 Maximal pressure switch 4 Minimal pressure switch 5 Permeate block 6 Membranes 7 Expansion tank 8 Expansion tank charge 9 PROFINE BLUE SMAL...

Page 8: ...pecifications listed in the CE plate with an efficient ground and protected by 0 03 mA differential switch If the power cord is damaged it must be replaced by the manufacturer dealer or a similarly qu...

Page 9: ...m drill bit drill a hole in the exhaust pipe of the siphon at the nut just disassembled Insert the drain pipe into the nut and tighten the nut on the bracket Tighten the nut and install the valve with...

Page 10: ...5 BLUE 105h BLACK 95h 8 WHITE 85h 7 5 BLACK 95h 7 HARDNESS F 11 12 25 26 35 36 44 Dh 5 6 15 16 20 21 25 WARNING After replacing the capillary set the filter change time in the control unit 4 8 WARNIN...

Page 11: ...s it with water permeate downstream of the membranes This device must be calibrated during installation Emergency BY PASS function with unplugged power supply system when it s open it lets the regular...

Page 12: ...ssing key the software release is displayed It performs the flushing of the membranes for 2 minutes by opening the inlet solenoid valve It resets the hours of operation of the filter Confirm with It d...

Page 13: ...the and keys and confirm with the key Select functioning by time or without time limitwith the and keys and confirm with the key Access the modification of the litres hour conversion parameter with t...

Page 14: ...It is advisable to carry out routine maintenance at least 1 time every 6 months even if you have not reached the limit of exhaustion of the filters WARNING This equipment should be serviced periodical...

Page 15: ...f the new cartridge in the provided space Insert the new cartridge without forcing it in any way making sure to enter the tabs in their own seats in the head and turn it 90 to the right until it stops...

Page 16: ...smotic water or dose 250 ml of hydrogen peroxide at 24 volumes per 10 liters of osmotic water or dose 180 ml of hydrogen peroxide at 36 volumes per 10 liters of osmotic water or dose 50 ml of hydrogen...

Page 17: ...e Reset the alarm see 4 6 If the alarm repeats or in case of water leakage close the upstream water supply valve unplug it and contact the assistance service Problem With the display turned on and wor...

Page 18: ...in hydraulic circuit Contact assistance service Problem With dishwasher in loading phase with display on the osmosis doesn t start Cause Solution Incorrect connections The in out links were inverted M...

Page 19: ...hazardous materials into the municipal waste stream The crossed out bin symbol reminds the user not to dispose of this product as unsorted municipal waste If disposed of privately exhausted filters a...

Page 20: ...cribed above is in conformity with the relevant Union harmonization legislation 2006 42 UE machines 2014 30 UE EMC 2014 35 UE LVD 2011 65 UE RHOS2 References to the relevant harmonized standards used...

Page 21: ...21 Cod 2050 0001 Rev 1 1 ATTACHMENT II MAINTENANCE LOG INSTALLATION TECHNICIAN TECHNICIAN TECHNICIAN REGULAR MAINTENANCE TECHNICIAN TECHNICIAN TECHNICIAN...

Reviews: